Popis: A prospective, objective assessment of ELSA use, in order to determine whether venting of the ELSA influences carbon dioxide (CO2) levels.Inspired and expired CO2 levels.On board RFA ARGUS during Operation TELIC.10 volunteers had a baseline of inspired and expired CO2 levels taken. These levels were measured at one minute intervals during use of an ELSA in 3 conditions--sitting, jogging and jogging with venting.There was no difference in expired CO2 levels between baseline and use of ELSA whilst sitting. Periodic venting of the ELSA made no difference to inspired and expired CO2 levels.Venting of the ELSA during use makes no difference to CO2 levels whether inspired or expired. Therefore, venting is unnecessary and potentially wastes vital time during escape from a smoke-filled compartment and adds additional stress to the escapee.