Effect of Intra-Canal Calcium Hydroxide Remnants on the Push-Out Bond Strength of Two Endodontic Sealers
Autor: | Ghabraei, Sholeh, Bolhari, Behnam, Yaghoobnejad, Fatemeh, Meraji, Naghmeh |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2017 |
Předmět: | |
Zdroj: | Iranian Endodontic Journal |
ISSN: | 2008-2746 1735-7497 |
Popis: | Introduction: The aim of this study was to evaluate the effect of intra-canal calcium hydroxide (CH) remnants after ultrasonic irrigation and hand file removal on the push out bond strength of AH-26 and EndoSequence Bioceramic sealer (BC Sealer). Methods and Materials: A total of 102 single-rooted extracted human teeth were used in this study. After root canal preparation up to 35/0.04 Mtwo rotary file, all the specimens received CH dressing except for 34 specimens in the control group. After 1 week, the specimens with CH were divided into 2 groups (n=34) based on the CH removal technique; i.e. either with ultrasonic or with #35 hand file. Then specimens were divided into two subgroups according to the sealer used for root canal obturation: AH-26 or BC Sealer. After 7 days, 1 mm-thick disks were prepared from the middle portion of the specimens. The push out bond strength and failure mode were evaluated. Data were analyzed by the two-way ANOVA and Tukey’s post hoc tests. Results: The push out bond strength of both sealers was lower in specimens receiving CH. These values were significantly higher when CH was removed by ultrasonic (P |
Databáze: | OpenAIRE |
Externí odkaz: |