Enantiomeric separation of amino acids and nonprotein amino acids using a particle-loaded monolithic column

Autor: M, Kato, M T, Dulay, B, Bennett, J, Chen, R N, Zare
Rok vydání: 2000
Předmět:
Zdroj: Electrophoresis. 21(15)
ISSN: 0173-0835
Popis: A solution is prepared of 5 microm silica particles modified with (S)-N-3,5-dinitrobenzoyl-1-naphthylglycine (particle 1) or (S)-N-3,5-dinitrophenylaminocarbonyl-valine (particle 2) suspended in liquid tetraethylorthosilicate, ethanol, and aqueous hydrochloric acid. This solution is injected under pressure into a 30 cm long, 75 microm inner diameter capillary column and heated for 1 h at 120 degrees C after which the modified particles are embedded in a monolithic column of sol gel. The packed column measures approximately 15 cm from the inlet to the window used to view the laser-induced fluorescence. Thirteen different amino acids and three nonprotein amino acids are derivatized with the fluorogenic reagent 4-fluoro-7-nitro-2,1,3-benzoxadiazole (NBD-F) before injection onto the column for capillary electrochromatographic separation. The enantiomeric separation of the monolithic column packed with particle 1 results in a resolution ranging from 1.14 to 4.45, whereas that packed with particle 2 results in a resolution ranging from 0.79 to 1.17. On the basis of resolution and amount of chiral packing material the enantiomeric separation obtained by capillary electrochromatography is judged to be superior to that obtained previously with high performance liquid chromatography (HPLC).
Databáze: OpenAIRE