A Modification of the Inverted Internal Limiting Membrane Flap Technique without Heavy Liquids and Prone Posturing

Autor: Klemens Paul, Kaiser, Sophie-Christin, Ernst, Gabor Mark, Somfai, Matthias Dieter, Becker, Florian Moritz, Heussen
Jazyk: němčina
Rok vydání: 2022
Zdroj: Klinische Monatsblatter fur Augenheilkunde.
ISSN: 1439-3999
Popis: Primary closure of large macular holes remains challenging, and variations of inverted inner limiting membrane (ILM) flap surgery have been described. In the present retrospective, interventional, single-centre case series, we propose a superior flap design with minimal posturing. Eight eyes of eight patients (four women and four men) in the period between July 2020 and March 2022 underwent 23 G three-port vitrectomy with a superior inverted ILM flap and 20% SFDer primäre Verschluss großer Makulaforamina ist nach wie vor eine Herausforderung, wobei verschiedene Varianten einer Operation mit einem inversen Lappen der Membrana limitans interna (MLI) beschrieben worden sind. In der vorliegenden retrospektiven interventionellen Fallserie eines einzelnen Zentrums präsentieren wir eine Lappentechnik mit minimaler postoperativer Lagerung. Acht Augen von 8 Patienten (4 Frauen und 4 Männer) unterzogen sich im Zeitraum zwischen Juli 2020 und März 2022 einer von demselben erfahrenen Chirurgen (FMH) durchgeführten 23-G-3-Port-Vitrektomie mit einem umgekehrten MLI-Lappen und einer 20%igen SF