Popis: |
Complement activation has been associated with numerous clinical hazards such as platelet aggregation, adult respiratory distress syndrome, and renal dysfunction. The complement system is activated by exposure of different biomaterials to blood. Recently a watertight knitted Dacron aortic prosthesis impregnated with bovine collagen has been developed. One potential disadvantage is that this bovine collagen may activate the complement system and evoke the production of inflammatory mediators. We conducted a prospective randomized trial to study the systemic effects of collagen-impregnated prostheses and of aortic surgery with implantation of Dacron prosthesis on the complement system in the perioperative period and at 3 months after operation. Forty-one patients randomly received either a collagen-impregnated (n = 20) or a nonimpregnated prosthesis (n = 21). Twelve patients who had cholecystectomy served as controls. CH50 consumption and C3a generation were determined to study overall complement activation. Furthermore, C3a/C3 fractions were calculated. Finally, C4 and factor B consumption were determined to evaluate the complement stimulation via the classic and the alternative pathways, respectively. We found significant activation of the complement system during the operation in both the collagen group (CH50 consumption: 40%, p = 0.03; C4 consumption: 74%, p0.0001; factor B consumption: 73%, p0.0001; C3a/C3 fraction increase: 173%,p = 0.04), and the nonimpregnated group (CH50 consumption: 40%, p0.0001; C4 consumption: 71%, p0.0001; factor B consumption: 76%, p0.0001; C3a/C3 fraction increase: 165%, p = 0.025), with no statistically significant differences between the groups of prostheses. Activation was initiated via both the classic and the alternative pathway. This indicates aortic implantation significantly activates the complement system, but that collagen-impregnated prostheses do not stimulate the complement system any more than its nonsealed substrate. Comparing results in patients with vascular disease with controls, a significantly increased complement activation was observed in the vascular group (CH50 consumption: 40%, p0.0001; C4 consumption: 74%, p0.0001; factor B consumption: 75%, p0.0001; C3a/C3 fraction: 169%, p = 0.002), compared with the controls (CH50 consumption: 71%; C4 consumption: 104%; factor B consumption: 94%; C3a/C3 fraction: 119%, all p = NS), with statistical significant differences between the vascular group and cholecystectomies (CH50: p = 0.005; C4: p = 0.002; factor B: p0.0001, and C3a/C3 fraction: NS). This observation demonstrates that aortic surgery with the implantation of a Dacron prosthesis significantly activates the complement system. |