Popis: |
A recently developed commercial rapid test kit (MIST Alert) was assessed for determination of the presence of paralytic shellfish poisoning (PSP) toxins in shellfish. Several commercially important shellfish species obtained from the UK shellfish toxin monitoring program, containing a range of total PSP toxicities as determined by the mouse bioassay (MBA), were tested. The kit detected toxin in all samples containing the European Community tolerance level of 80 microg saxitoxin (STX) equivalents/100 g shellfish flesh as determined by the MBA. With one exception, the kit detected toxin in all samples that contained40 microg STX equivalents/100 g according to the MBA. Among samples in which the MBA did not detect toxin, the kit disagreed in 25% of the tests, although further analysis by liquid chromatography (LC) and MBA of some samples confirmed the presence of toxins. These results suggest that MIST Alert may be suitable as an initial screen for PSP toxins as part of routine monitoring programs, thereby greatly reducing the number of MBAs. Trials were also performed by nonscientific personnel to evaluate the ease of use and interpretation of results obtained by MIST Alert. The results indicated that the kits could be readily used and accurately interpreted by individuals with no technical or scientific background. |