Autor: |
Karla R, Feeser, Vitaliano, Cama, Jeffrey W, Priest, Elizabeth A, Thiele, Ryan E, Wiegand, Thomson, Lakwo, Sindew M, Feleke, Paul T, Cantey |
Rok vydání: |
2017 |
Předmět: |
|
Zdroj: |
The American journal of tropical medicine and hygiene. 97(3) |
ISSN: |
1476-1645 |
Popis: |
Multiplex bead assays (MBAs) may provide a powerful integrated tool for monitoring, evaluation, and post-elimination surveillance of onchocerciasis and co-endemic diseases; however, the specificity and sensitivity of Onchocerca volvulus antigens have not been characterized within this context. An MBA was developed to evaluate three antigens (OV-16, OV-17, and OV-33) for onchocerciasis. Receiver operating characteristics (ROC) analyses were used to characterize antigen performance using a panel of 610 specimens: 109 O. volvulus-positive specimens, 426 non-onchocerciasis controls with filarial and other confirmed parasitic infection, and 75 sera from patients with no other parasitic infection. The IgG and IgG4 assays for OV-16 demonstrated sensitivities of 95.4% and 96.3%, and specificities of 99.4% and 99.8%, respectively. The OV-17 IgG and IgG4 assays had sensitivities of 86.2% and 76.1% and specificities of 79.2% and 82.8%. For OV-33, the IgG and IgG4 assays had sensitivities of 90.8% and 96.3%, and specificities of 96.8% and 98.6%. The OV-16 IgG4-based MBA had the best assay characteristics, followed by OV-33 IgG4. The OV-16 IgG4 assay would be useful for monitoring and evaluation using the MBA platform. Further evaluations are needed to review the potential use of OV-33 as a confirmatory test in the context of program evaluations. |