Maternal alloanti-hrS--an absence of HDN

Autor: R, Kakaiya, J, Cseri, B, Jochum, L, Gillard, S, Silberman
Rok vydání: 2004
Předmět:
Zdroj: Immunohematology. 20(3)
ISSN: 0894-203X
Popis: A 24-year old female, gravida III, para III, delivered a full-term infant by cesarean section. A maternal blood sample at the time of admission showed antibody in her serum that had apparent anti-e specificity and that her RBCs were e+. Further studies determined that the antibody was anti-hrS. Cord RBCs had a negative DAT and a normal Hb level. There was no clinical evidence for increased hemolysis in the infant. We describe an hrS+ infant with no evidence of HDN due to anti-hrS.