Vibrational angioplasty and hydrophilic guidewires in the treatment of chronic total coronary occlusions

Autor: Michalis, L. K., Rees, M. R., Davis, J. A., Pappa, E. C., Katsouras, C., Goudevenos, J., Sideris, D. A.
Jazyk: angličtina
Rok vydání: 2000
Předmět:
Popis: PURPOSE: To study the efficacy and safety of vibrational angioplasty versus hydrophilic guidewires for recanalizing chronic total occlusions (CTOs) of the coronary arteries. METHODS: In a retrospective study, 99 patients with old (>3 months) CTOs resistant to conventional techniques were treated either with vibrational angioplasty (group A, n = 72) or 0.014-inch hydrophilic guidewires (group B, n = 27). The selection of the technique (vibrational angioplasty or hydrophylic guidewires) was dependent only upon device availability. A variety of guidewires were employed in conjunction with vibrational angioplasty. RESULTS: The crossing success rates in groups A and B were 86.1% (62/72) and 55.5% (15/27) (p < 0.05), with final procedural success rates of 75% (54/72) and 44.4% (12/27) (p < 0.01), respectively. The main reasons for failure were inability to cross the lesion with a guidewire (10/18 in group A and 12/15 in group B) and large dissections resulting in vessel closure (2/18 in group A and 2/15 in group B). Three major complications were seen, 2 in group A and 1 in group B. Three vessel perforations were reported in group A. Both techniques needed prolonged fluoroscopy times. CONCLUSIONS: Vibrational angioplasty was more successful in treating CTOs compared to hydrophilic guidewires and had similar complication rates (most without clinical sequelae). J Endovasc Ther