Design of heating and ventilation system for a cultural center building

Autor: Slivar, Teo
Přispěvatelé: Smoljan, Darko
Jazyk: chorvatština
Rok vydání: 2022
Předmět:
Popis: U ovom radu prikazano je projektno rješenje sustava grijanja i mehaničke ventilacije zgrade kulturnog centra. Zgrada se nalazi na području Bjelovarsko – bilogorske županije u gradu Daruvaru te se proteže na dvije etaže (Pr+Po) sa suterenom u kojem se nalazi određeni dio strojarskog postrojenja. Korisna površina objekta iznosi 475 m2. U prostorijama većih dimenzija (sala za sastanke, multimedijska dvorana, izložbeni prostor i višenamjenska dvorana za mlade) u kojima će boraviti veći broj ljudi kao izvor topline predviđeno je podno grijanje s niskotemperaturnim režimom rada 38/32 oC. U svim ostalim prostorijama prizemlja i potkrovlja predviđen je srednjetemperaturni režim grijanja 65/50 oC s radijatorima. Kao centralni izvor topline cijelog sustava koristi se kotao na biomasu (drvna sječka ili peleti) proizvođača Centrometal. Ukupno projektno toplinsko opterećenje zgrade proračunato je prema normi HRN EN 12831-1:2017, a proračun je proveden u programu IntegraCAD. Za navedenu zgradu ono iznosi 18969 W. Kotao, akumulacijski spremnik, ekspanzijska posuda i ostatak opreme za grijanje zgrade nalazi se u strojarnici koja se nalazi u suterenskom dijelu zgrade. Sustav mehaničke ventilacije projektiran je kao sustav s varijabilnim protočnim volumenom zraka u ovisnosti o koncentraciji CO2. Sustav je zamišljen je kao sustav s povratom topline preko rekuperatora. Za potrebe mehaničke ventilacije najvećih prostorija (multimedijska dvorana, izložbeni prostor i višenamjenska dvorana za mlade) odabrane su zasebne ventilacijsko - rekuperacijske jedinice proizvođača Daikin, dok se ventilacijski sustav ostalih prostorija vrši preko zajedničke jedinice istog proizvođača. Sve ventilacijsko – rekuperacijske jedinice nalaze se u spremištu u suterenskom dijelu zgrade. Sve jedinice su izvedene kao stropne s horizontalnim priključcima. U prilogu se nalaze tablice s rezultatima proračuna i crteži koji prikazuju raspored opreme te funkcionalne sheme spajanja i automatsku regulaciju. This paper present design solution for heating and mechanical ventilation system for the cultural center. The building is located in Bjelovar – bilogora County area Daruvar and extends to two floors (G+A) with a basement where a certain part of the equipment is located. The useful area of the building is 475 m2 . In the larger rooms (meeting hall, multimedia hall, exhibition space and multipurpose hall) where most of people resides, underfloor heating is provided as a source of heat with a low – temperature mode 38/32 oC. In all other rooms on the ground floor and attic, heating is used with medium – temperature mode 65/50 oC with radiators. A biomass boiler manufactured by Centrometal is used as a heat source for the entire system. The total project losses of the building were calculated according to the HRN EN 12831-1:2017 standard, and the calculation was carried out in the IntegraCAD software. For specified building it amounts 18969 W. The boiler, storage tank, expansion vessel and the rest of equipment are located in the machine room located in the basement. The mechanical ventilation system is designed as variable air volume system depending on carbone dioxide concentration. The system is designed as a system with heat recovery over a recuperator. The separate ventilation energy recovery units manufactured by Daikin where chosen for the mechanical ventilation purposes of the biggest rooms (meeting hall, multimedia hall, exhibition space and multipurpose hall), while the ventilation system of the other rooms is carried out through a common unit of the same manufacturer. All the ventilation energy recovery units are located in the basement storage room. All units are ceiling - mounted with horizontal connections. Attachments contain tables with calculation results, drawings showing the layout of the equipment, and the functional scheme of the connection and automatic regulation.
Databáze: OpenAIRE