Search for time dependent signatures in Dark Matter detector

Autor: Todorović, Doris
Přispěvatelé: Karuza, Marin
Jazyk: chorvatština
Rok vydání: 2021
Předmět:
Popis: Mnoga indirektna astronomska i kozmološka opažanja, kao što su mjerenja rotacijskih krivulja spiralnih galaksija te efekata gravitacijske lece, predstavljaju uvjerljive dokaze o postojanju tamne materije. Očekivani eksperimentalni potpisi tamne tvari, prema standardnom halo modelu, sastoje se od godišnje i dnevne modulacije. Prethodno razvijeni optomehanički detektor sa silicij nitridnom membranom i površinskim slojem platine, korišten je u četveromjesečnom razdoblju kontinuiranog prikupljanja podataka, fokusiranom na opažanje pretpostavljenih vremenski ovisnih signala tamne materije. Pomak membrane je detektiran modificiranim Michelsonovim interferometrom uporabom tehnike optičke homodine. Glavna observabla u ovom esperimentalnom postavu je frekvencija termalno induciranog rezonantnog vrha membrane. Zbog velike količine prikupljenih podataka, ključno je bilo implementirati paralelizaciju u posvećenom Python kodu kako bi se konstruirao skup podataka korišten u sljedećim koracima analize. Nakon automatizirane analize provedene na superračunalu BURA, slijedi lokalna optimizirana obrada primjenom dvije neovisne metode; računanje Lomb-Scargle periodograma i preklapanje podataka u 24-satnom periodu u terminima sinodičkog i sideričkog vremena. Opažena je dnevna modulacija u mjerenjima frekvencije pri sobnim temperaturama, kao funkcija lokalnog sideričkog vremena. Karakterizacija moduliranog signala ukazuje na period oscilacije jednak (0,52 ± 0,02) rad/h, sto je u skladu ˇ s interpretacijom o dnevnoj modulaciji signala tamne materije mjerenog zemaljskim detektorom. Potrebna su daljnja mjerenja i dodatne analize kako bi se odredili mogući doprinosi detektorskoj pozadini, gornja granica mase te potvrdila interpretacija interakcije toka cestica tamne materije s detektorskom membranom. Many indirect astronomical and cosmological observations, such as measurements of rotational curves of spiral galaxies and gravitational lensing, introduce substantial evidence for the existence of dark matter. Expected experimental signatures of dark matter, according to the Standard Halo Model, consist of annual and diurnal modulation. A previously developed optomechanical detector with silicon nitride, platinum-coated membrane was employed in a four-month-long data-taking campaign focused on obtaining hypothesized time-dependent dark matter signals. The membrane displacement is detected by the modified Michelson interferometer and optical homodyne technique. The main observable in this experimental setup is frecquency of a membrane’s thermally induced resonant peak. Due to a large amount of stored data, the implementation of parallel computing in dedicated Python code was crucial to obtain relevant dataset used in the proceeding steps of the analysis pipeline. After the automated analysis was done on supercomputer BURA, local optimized analysis using two independent methods followed. Here either the Lomb-Scargle periodogram is calculated or, the data points are folded using a 24 hour period in terms of local synodic and sidereal time. A presence of daily modulation in frequency measurements as a function of local sidereal time is reported at a range of room temperatures. Characterization of modulated signal suggests a period of oscillation (0,52 ± 0,02) rad/h consistent with daily modulation interpretation of a dark matter signal measured by Earth-based detector. Further measurements and discussions are necessary concerning possible background contributions, mass upper-limit as well as confirmation of dark matter flux interpretation of the interaction with the detector membrane.
Databáze: OpenAIRE