Long-term clinical outcomes after bioresorbable vascular scaffold implantation for the treatment of coronary in-stent restenosis
Autor: | Moscarella E., Ielasi A., Granata F., Coscarelli S., Stabile E., Latib A., Cortese B., Tespili M., Tanaka A., Capozzolo C., Caliendo L., Colombo A., Varricchio A. |
---|---|
Přispěvatelé: | Moscarella, E., Ielasi, A., Granata, F., Coscarelli, S., Stabile, E., Latib, A., Cortese, B., Tespili, M., Tanaka, A., Capozzolo, C., Caliendo, L., Colombo, A., Varricchio, A. |
Jazyk: | angličtina |
Rok vydání: | 2016 |
Předmět: |
Male
Registrie Time Factor Metal Risk Factor Myocardial Infarction Coronary Artery Disease Kaplan-Meier Estimate Middle Aged Prosthesis Design Prospective Studie Treatment Outcome Percutaneous Coronary Intervention Italy Coronary Restenosi Recurrence Absorbable Implant Proportional Hazards Model Drug-Eluting Stent stent Female Stents Human Aged |
Popis: | Background - Treatment of in-stent restenosis (ISR) is still challenging. In this setting, the use of bioresorbable vascular scaffold (BVS) seems attractive because it allows drug delivery combined with transient vessel scaffolding. We aimed to investigate the long-term results after BVS use in ISR lesions. Methods and Results - A prospective analysis was performed on all patients who underwent percutaneous coronary intervention with BVS implantation for ISR at 7 Italian Centers. Primary end point was the device-oriented composite end point (cardiac death, target vessel myocardial infarction, and ischemia-driven target lesion revascularization) at the longest follow-up available. From April 2012 to June 2014, 116 patients (127 lesions) underwent percutaneous coronary intervention for ISR with BVS implantation. Among the ISR lesions, the majority were drug-eluting stent ISR (78, 61.6%), de novo ISR (92, 72.4%), and diffuse ISR (81, 63.8%). Procedural success was achieved for all (100%) patients. No in-hospital death, myocardial infarction, or revascularization occurred. At 15 months of follow-up, the incidence of the device-oriented composite end point estimated with the Kaplan-Meier method was 9.1%. No significant differences were reported between drug-eluting stent and bare-metal stent ISR groups in terms of device-oriented composite end point (10.9% versus 6.4%; hazard ratio, 1.7; 95% confidence interval, 0.5-6.5; P=0.425) and its singular components (cardiac death: 2.8% versus 2.0%, hazard ratio, 1.3; 95% confidence interval, 0.1-14.1, P=0.843; target vessel myocardial infarction: 1.5% versus 0%, P=0.421; ischemia-driven target lesion revascularization: 9.6% versus 4.4%, hazard ratio, 2.3; 95% confidence interval, 0.5-10.8, P=0.309). Conclusions - Our registry suggests that the use of BVS implantation for the treatment of complex drug-eluting stent and bare-metal stent ISR lesions might be associated with acceptable long-term clinical outcomes. |
Databáze: | OpenAIRE |
Externí odkaz: |