Application of electrical imaging in the study of contamination from cemeteries
Autor: | Silva, Robson Willians da Costa, Malagutti Filho, Walter [UNESP] |
---|---|
Přispěvatelé: | Universidade de São Paulo (USP), Universidade Estadual Paulista (Unesp) |
Jazyk: | portugalština |
Rok vydání: | 2010 |
Předmět: | |
Zdroj: | Scopus Repositório Institucional da UNESP Universidade Estadual Paulista (UNESP) instacron:UNESP |
Popis: | Submitted by Vitor Silverio Rodrigues (vitorsrodrigues@reitoria.unesp.br) on 2014-05-27T11:24:50Z No. of bitstreams: 0Bitstream added on 2014-05-27T14:46:57Z : No. of bitstreams: 1 2-s2.0-78149232932.pdf: 6403471 bytes, checksum: 537204277b0754a692475c91ce5bc71e (MD5) Made available in DSpace on 2014-05-27T11:24:50Z (GMT). No. of bitstreams: 0 Previous issue date: 2010-11-12 Devido à falta de proteção ambiental com a qual o procedimento de enterrar os corpos foi conduzido ao longo das décadas, muitos dos cemitérios se tornaram áreas contaminadas, por substâncias orgânicas e inorgânicas, e microrganismos patogênicos. Neste trabalho são apresentados os resultados do imageamento elétrico na delimitação de áreas potencialmente contaminadas por necrochorume, no cemitério municipal de Vila Rezende, Piracicaba - SP. Os resultados indicam uma profundidade do nível freático entre 3,1 e 5,1 m, com duas direções de fluxo subterrâneo, uma a SW e outra a SE. Tanto as prováveis plumas de contaminação, que tem as mesmas direções de fluxo subterrâneo, quanto às anomalias condutivas verificadas nas seções geoelétricas, confirmam as suspeitas de contaminação na área. A provável pluma a SE prolonga-se para fora dos limites do cemitério. A localização das anomalias condutivas e das prováveis plumas de contaminação demonstrou que a contaminação tem ligação com a profundidade do nível freático e com o tempo de sepultamento. Palavras-chave: imageamento elétrico, cemitério, necrochorume. Due to lack of environmental protection with which the process of burying the corpses was conducted over the decades, many cemeteries have become areas contaminated by organic and inorganic substances and pathogenic microrganisms. This paper presents the results of electrical imaging in delineation of areas potentially contaminated by necrochorume in the municipal cemetery of Vila Rezende, Piracicaba - SP. The results indicate a depth of water table among 3,1 and 5,1 m, with two flow directions, being one to SW and another to SE. So the probable contamination plume, that has the same directions of underground flow, as for the conductive anomalies verified at the geoelectrics sections confirm the suspicions of contamination in the area. The probable plume the SE is prolonged to out of the cemetery. The location of the conductive anomalies and likely contamination plumes demonstrated that the contamination is linked with the depth of water table level and the burial time. Laboratório de Ecologia Isotópica Centro de Energia Nuclear na Agricultura Universidade de São Paulo, Avenida Centenário, 303 - São Dimas, CEP 13416-000. Piracicaba, SP Departamento de Geologia Aplicada Instituto de Geociências e Ciências Exatas Universidade Estadual Paulista, Campus de Rio Claro, Avenida 24 - A, 1515 - Bela Vista, CEP 13506-900. Rio Claro, SP Departamento de Geologia Aplicada Instituto de Geociências e Ciências Exatas Universidade Estadual Paulista, Campus de Rio Claro, Avenida 24 - A, 1515 - Bela Vista, CEP 13506-900. Rio Claro, SP |
Databáze: | OpenAIRE |
Externí odkaz: |