Temperature profiles of different cooling methods in porcine pancreas procurement

Autor: Weegman, B.P. Suszynski, T.M. Scott, W.E., III Ferrer Fábrega, J. Avgoustiniatos, E.S. Anazawa, T. O'Brien, T.D. Rizzari, M.D. Karatzas, T. Jie, T. Sutherland, D.E.R. Hering, B.J. Papas, K.K.
Jazyk: angličtina
Rok vydání: 2014
Popis: Porcine islet xenotransplantation is a promising alternative to human islet allotransplantation. Porcine pancreas cooling needs to be optimized to reduce the warm ischemia time (WIT) following donation after cardiac death, which is associated with poorer islet isolation outcomes. This study examines the effect of four different cooling Methods on core porcine pancreas temperature (n = 24) and histopathology (n = 16). All Methods involved surface cooling with crushed ice and chilled irrigation. Method A, which is the standard for porcine pancreas procurement, used only surface cooling. Method B involved an intravascular flush with cold solution through the pancreas arterial system. Method C involved an intraductal infusion with cold solution through the major pancreatic duct, and Method D combined all three cooling Methods. Surface cooling alone (Method A) gradually decreased core pancreas temperature to