Seismic behaviour of composite shear wall with steel reinforced concrete frame and embedded perforated-steel plate
Autor: | Zhou, Zhongyi, Cao, Wanlin, Liu, Yan, Li, Jianhua |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | Građevinar Volume 74 Issue 05. |
ISSN: | 1333-9095 0350-2465 |
Popis: | U radu se ispituje pet uzoraka posmičnih stijena raznih dimenzijskih i konstrukcijskih karakteristika kako bi se istražilo seizmičko ponašanje spregnute posmične stijene s armiranobetonskim okvirom ojačanim čelikom i ugrađenom perforiranom čeličnom pločom. Osim toga, niskociklično opterećenje se nanosi na uzorke s koeficijentom posmične zone od 1,5. Eksperimentalni podaci koriste se za analizu nosivosti, krutosti, duktilnosti, histerezne energije i karakteristika otkazivanja spomenutih uzoraka. Rezultati pokazuju da se spregnuta posmična stijena s armiranobetonskim okvirom ojačanim čelikom i ugrađenom čeličnom pločom odlikuje većom nosivošću, boljom duktilnošću, sporijim padom krutosti te većom sposobnošću rasapa energije u usporedbi s običnim armiranobetonskim posmičnim zidom. Osim toga, primjenom ugrađenih čeličnih ploča odgovarajuće debljine poboljšava se i seizmičko ponašanje spregnutih posmičnih stijena. Analizom čeličnih ploča iste debljine utvrđeno je da se uzorci s čeličnim vezicama seizmički bolje ponašaju od uzoraka sa zavarenim svornjacima. U završnom je dijelu razvijen računalni model za izračunavanje nosivosti CSW-a. Usporedba pokazuje dobru podudarnost rezultata proračuna i rezultata dobivenih mjerenjem. Experiments are conducted on five shear wall specimens of varying design and structural measures in order to investigate seismic behaviour of a composite shear wall with the steel-reinforced concrete frame and an embedded perforated-steel plate. In addition, low-cyclic load is applied on test specimens that have a shear span ratio of 1.5. Using the experimental data, the bearing capacity, stiffness, ductility, hysteretic energy, and failure characteristics of five specimens are analysed. The results show that the composite shear wall (CSW) with the steel reinforced concrete frame (SRCF) and embedded steel plate (ESP) has higher bearing capacity, better ductility, slower degradation of stiffness, and higher energy dissipation capacity, as compared to an ordinary reinforced concrete shear wall. Moreover, its seismic behaviour can be improved by using the ESP of an appropriate thickness. For the ESPs of identical thickness, the results show that the specimen that uses steel ties exhibits better seismic behaviour than those using welding studs. Finally, a computing model that can calculate the bearing capacity of the CSWs is developed. A comparison of calculated and measured results shows that the results are close to each other. |
Databáze: | OpenAIRE |
Externí odkaz: |