EMG I GRF ANALIZA PRI IZVOÐENJU KORAK DOKORAKA NA RAZLIČITIM VISINAMA STEP KLUPICE
Autor: | Maja Horvatin-Fučkar, Jadranka Vlašić, Drena Trkulja-Petković |
---|---|
Jazyk: | chorvatština |
Rok vydání: | 2013 |
Předmět: | |
Zdroj: | Hrvatski športskomedicinski vjesnik Volume 28 Issue 1 |
ISSN: | 0354-0766 |
Popis: | Ovo istraživanje je provedeno s ciljem utvrðivanja nekih prediktivnih biomehaničkih pokazatelja: elektromiografska aktivnost (EMG) nogu i kinetički parametri sile reakcije podloge (GRF) tijekom izvoðenja dinamičkog pokreta penjanja i spuštanja na razlièite visine step klupice korak dokorakom. Mjerenje EMG signala provedeno je 8-kanalnim (TELEMG) sustavom kojim su praćeni dominantni, karakteristični mišići nogu: m. rectus femoris, m. biceps (caput longum), m. gastrocnemius medialis, m. gluteus maximus. Kinetički signali su izmjereni Kistler platformom za mjerenje sile reakcije podloge, tipa 9281C, uz frekvenciju uzrokovanja od 1000 Hz. Mjerenjem je bilo obuhvaćeno 9 ispitanika, dugogodišnjih profesionalnih voditelja step aerobike. Analizom osnovnih statističkih parametara obraðenih EMG signala promatranih mišića najveći utrošak energije imao je: m. gastrocnemius medialis (L), zatim m. biceps femoris (L), m. rectus femoris (D), te m gastocnemius medialis (D). Wilcoxon-ov test ekvivalentnih parova je dokazao da postoje očekivano statistički značajne razlike u intenzitetu mišićne kontrakcije povećanjem intenziteta opterećenja s povišenjem step klupice. Osnovni statistički parametri sile reakcije podloge (GRF) ukazuju na najveće vrijednosti u vektorima sile Fz i Fy, kao i statistički značajne razlike na različitim visinama step klupice što je uvjetovano povećanjem amplitude pokreta, a time i većim intenzitetom opterećenja pri silasku na mjernu platformu i penjanju na veće visine step klupice. The main goal of this research was to establish some predictive biomechanical performance indicators: electromyographic activities (EMG) of leg muscles and kinetics parameters of ground reaction force (GRF) during dynamical movements stepping on and off at different heights of step bench performing the step touch. Measuring EMG signals was made by 8-channel (TELEMG) system monitoring the dominant, characteristic of both legs muscles: m. rectus femoris, m. biceps (caput longum), m. gastrocnemius medialis, m. gluteus maximus. Kinetics signals was measured by Kistler platform for ground reaction force type 9281C, with frequency of sampling 1000 Hz. The measuring procedures included 9 examinees, long-time professional step aerobics instructors. By analyzing the basic statistics parameters from the processed EMG signals highest energy consumption had: m. gastrocnemius medialis (L), then m. biceps femoris (L), m. rectus femoris (R), and m gastocnemius medialis (R). Wilcoxon matched pairs test has proved that there are statistically significant difference in muscle contraction intensity when increasing the exertion intensity by increasing the height of the step bench. The basic statistics parameters of the ground reaction force (GRF) indicate the greatest values in vectors Fz and Fy, as statistically significant differences between different height of the step bench conditional increasing the amplitude of movement and increasing the intensity during stepping on and off at different heights of step bench. |
Databáze: | OpenAIRE |
Externí odkaz: |