Ultralow energy calibration of LUX detector using Xe-127 electron capture

Autor: Akerib, DS, Alsum, S, Araujo, HM, Bai, X, Bailey, AJ, Balaithy, J, Beltrame, P, Bernard, EP, Bernstein, A, Biesiadzinski, TP, Boulton, EM, Bras, P, Byram, D, Cahn, SB, Carmona-Benitez, MC, Chan, C, Currie, A, Cutter, JE, Davison, TJR, Dobi, A, Druszkiewicz, E, Edwards, BN, Fallon, SR, Fan, A, Fiorucci, S, Gaitskell, RJ, Genovesi, J, Ghang, C, Gilchriese, MGD, Hall, CR, Hanhardt, M, Haselschwardt, SJ, Hertel, SA, Hogan, DP, Horn, M, Huang, DQ, Ignarra, CM, Jacobsen, RG, Ji, W, Kamdin, K, Kazkaz, K, Khaitan, D, Knoche, R, Larsen, NA, Lenardo, BG, Lesko, KT, Lindote, A, Lopes, MI, Manalaysay, A, Mannino, RL, Marzioni, MF, McKinsey, DN, Mei, D-M, Mock, J, Moongweluwan, M, Morad, JA, Murphy, ASJ, Nehrkom, C, Nelson, HN, Neves, F, O'Sullivan, K, Oliver-Mallory, KC, Palladino, KJ, Pease, EK, Rhyne, C, Shaw, S, Shutt, TA, Silva, C, Solmaz, M, Solovov, VN, Sorensen, P, Sumner, TJ, Szydagis, M, Taylor, DJ, Taylor, WC, Tennyson, BP, Terman, PA, Tiedt, DR, To, WH, Tripathi, M, Tvrznikova, L, Uvarov, S, Velan, V, Verbus, JR, Webb, RC, White, JT, Whitis, TJ, Witherell, MS, Wolfs, FLH, Xu, J, Yazdani, K, Young, SK, Zhang, C
Jazyk: angličtina
Rok vydání: 2017
Předmět:
Zdroj: Akerib, DS; Alsum, S; Araujo, HM; Bai, X; Bailey, AJ; Balaithy, J; et al.(2017). Ultralow energy calibration of LUX detector using Xe-127 electron capture. PHYSICAL REVIEW D, 96(11). doi: 10.1103/PhysRevD.96.112011. Lawrence Berkeley National Laboratory: Retrieved from: http://www.escholarship.org/uc/item/9fn179bq
Popis: We report an absolute calibration of the ionization yields($\textit{Q$_y$})$ and fluctuations for electronic recoil events in liquid xenon at discrete energies between 186 eV and 33.2 keV. The average electric field applied across the liquid xenon target is 180 V/cm. The data are obtained using low energy $^{127}$Xe electron capture decay events from the 95.0-day first run from LUX (WS2013) in search of Weakly Interacting Massive Particles (WIMPs). The sequence of gamma-ray and X-ray cascades associated with $^{127}$I de-excitations produces clearly identified 2-vertex events in the LUX detector. We observe the K- (binding energy, 33.2 keV), L- (5.2 keV), M- (1.1 keV), and N- (186 eV) shell cascade events and verify that the relative ratio of observed events for each shell agrees with calculations. The N-shell cascade analysis includes single extracted electron (SE) events and represents the lowest-energy electronic recoil $\textit{in situ}$ measurements that have been explored in liquid xenon.
Databáze: OpenAIRE