Popis: BACKGROUND: Clinimetric data for the fire fighting simulation test (FFST), a new test proposed for the Workers' Health Surveillance (WHS) of Dutch fire fighters, were evaluated. METHODS: Twenty-one fire fighters took the FFST three times with one and three weeks between testing. Clinimetric quality was determined by means of reliability, agreement and validity. For reliability and agreement, the intraclass correlation coefficient (ICC), and standard error of measurement (SEM), were analysed. For construct validity, the tests from 45 fire fighters were correlated with their own and their supervisors' rated work ability. RESULTS: The ICCs were 0.56 and 0.79 at the one-week and three-week test-retest periods, respectively. Testing times ranged from 9 to 17 minutes; the SEMs were 70 s at the one-week and 40 s at the three-week test-retest periods. The construct validity was moderate (-0.47 [less than or equal to] r [less than or equal to] -0.33; p