Validation on thermal cycle degradation of ADEOS-2 power supply harness
Autor: | Neish, Michael J., Ishizawa, Junichiro, Baba, Naoko, Minami, Shintaro, Imagawa, Kichiro, Kurosaki, Tadaaki, Maejima, Hironori, Kojima, Yasushi |
---|---|
Jazyk: | japonština |
Rok vydání: | 2005 |
Předmět: | |
Zdroj: | 宇宙航空研究開発機構特別資料: 第1回宇宙環境シンポジウム報告書 = JAXA Special Publication: Proceedings of the First Spacecraft Environment Symposium. :100-106 |
ISSN: | 1349-113X |
Popis: | On October 25, 2004 ADEOS-2 (Advanced Earth Observing Satellite-2; Midori-2) ceased supplying observational data owing to a catastrophic power failure. FTA (Fault Tree Analysis) suggested that a rupture or short circuit of the power harness between the PDL (Solar Array Paddle Subsystem) and the electric power subsystem was the most likely cause. Material tests were conducted on the harness to elucidate the failure mechanism. High-temperature thermal cycling was seen to lead to anomalous expansion and contraction of the harness cable insulators. This phenomenon resulted in abrasion and fatigue of these materials. 資料番号: AA0048468019 レポート番号: JAXA-SP-04-010 |