Hypovolemic Status in Older Hip Fracture Patients Elucidated by Preoperative Transthoracic Echocardiography
Autor: | Toru Kaneda, Yasuhiro Watanabe |
---|---|
Rok vydání: | 2021 |
Předmět: |
Cardiac function curve
medicine.medical_specialty Cardiac output Hip fracture Ejection fraction Article Subject business.industry Cardiac index Stroke volume Critical Care and Intensive Care Medicine medicine.disease Inferior vena cava Anesthesiology and Pain Medicine medicine.vein Anesthesiology Internal medicine medicine Intravascular volume status Cardiology RD78.3-87.3 business Research Article |
Zdroj: | Anesthesiology Research and Practice, Vol 2021 (2021) Anesthesiology Research and Practice |
ISSN: | 1687-6970 1687-6962 |
DOI: | 10.1155/2021/9243945 |
Popis: | Older patients undergoing hip fracture surgery often experience intraoperative hemodynamic instability despite maintaining cardiac function. Although preoperative hemodynamics in such patients have been demonstrated mainly through invasive monitoring, few studies have addressed hemodynamics based on noninvasively measured parameters. We aimed to investigate preoperative hemodynamic states in older hip fracture patients using transthoracic echocardiography (TTE). The TTE data of patients aged >75 years who underwent hip fracture surgery or elective total hip arthroplasty (THA) between April 1, 2019, and March 31, 2021, were collected. In addition to the baseline characteristics, the TTE data from hip fracture patients were compared with the data of those who underwent THA. The hip fracture patients (n = 167) were significantly older and had lower stroke volume (45.6 vs. 50.9 ml; p < 0.01 ) and stroke index (33.7 vs. 36.6 ml/m2; p < 0.01 ) compared to those who underwent elective THA (n = 44). However, the cardiac output (3.51 vs. 3.48 L/min; p = 0.273 ) and cardiac index (2.6 vs. 2.47 L/min/m2; p = 0.855 ) for both groups were almost identical due to the increase in heart rate in the hip fracture group. Regarding other parameters including ejection fraction, fractional shortening, E/E′, and inferior vena cava diameter, there were no significant differences between the two groups. Our noninvasive TTE investigations suggested that hip fracture patients were volume-depleted, and the hypovolemic status activated the sympathetic nervous system, compensating for their cardiac output. Anesthesiologists must focus on the TTE-assessed parameters reflecting the volume status along with the cardiac function. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |