First Experience With the ICD 16.5 Mini-Scleral Lens for Optic and Therapeutic Purposes
Autor: | Stéphane Galiacy, Myriam Cassagne, François Malecaze, Pierre Fournié, Vincent Soler, Benoît Lepage, Virginie Madariaga, René Mely, Cyrielle Suarez, Marie Malecaze |
---|---|
Přispěvatelé: | Epidémiologie et analyses en santé publique : risques, maladies chroniques et handicaps (LEASP), Université Toulouse III - Paul Sabatier (UT3), Université Fédérale Toulouse Midi-Pyrénées-Université Fédérale Toulouse Midi-Pyrénées-Institut National de la Santé et de la Recherche Médicale (INSERM) |
Rok vydání: | 2018 |
Předmět: |
Adult
Male Keratoconus medicine.medical_specialty Visual acuity Adolescent genetic structures [SDV]Life Sciences [q-bio] Visual Acuity Prosthesis Design Corneal Diseases law.invention Young Adult 03 medical and health sciences 0302 clinical medicine Lens Implantation Intraocular Scleral lens law Ophthalmology Humans Medicine Prospective Studies Child Prospective cohort study ComputingMilieux_MISCELLANEOUS Aged Lenses Intraocular business.industry Middle Aged medicine.disease eye diseases Confidence interval Surgery Sclera Contact lens Lens (optics) Treatment Outcome medicine.anatomical_structure Child Preschool 030221 ophthalmology & optometry Female sense organs medicine.symptom business 030217 neurology & neurosurgery Follow-Up Studies |
Zdroj: | Eye and Contact Lens Eye and Contact Lens, Lippincott, Williams & Wilkins, 2018, ⟨10.1097/ICL.0000000000000293⟩ |
ISSN: | 1542-2321 |
DOI: | 10.1097/icl.0000000000000293 |
Popis: | OBJECTIVES To evaluate the success rate, efficacy, and safety of the ICD 16.5 mini-scleral gas permeable (GP) contact lens. METHODS This prospective study included referred consecutive patients with irregular corneas and severe ocular surface disease (OSD) in treatment failure. All patients were fitted with the ICD 16.5 mini-scleral GP lens. Even though we had some limited experience with scleral lenses, it was our first experience with the ICD 16.5 mini-scleral GP lens. Efficacy was assessed by comparing best-corrected visual acuity (BCVA) with the mini-scleral lens to baseline BCVA. A subjective visual functioning questionnaire (comfort score, visual quality score, handling rating, and wearing time) was administered in a face-to-face structured interview. RESULTS Thirty-nine eyes of 23 patients with a mean age of 43±16 years were included. Fitting indications were keratoconus (46%), post-penetrating keratoplasty (21%), other irregular astigmatism (15%), and severe OSD (18%). Twenty-five eyes (64%) were successfully fitted with an 18-month follow-up. The mini-scleral GP lens BCVA was 0.16 logarithm of the minimum angle of resolution (logMAR; 20/25) versus a baseline BCVA of 0.44 logMAR (20/63; P |
Databáze: | OpenAIRE |
Externí odkaz: |