Doppler assessment of fetal aortic isthmus flow in twin
Autor: | Soon Pyo Lee, Han Na Park, Chae Min Lee, Sun Young Jung, Suk Young Kim |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2015 |
Předmět: |
medicine.medical_specialty
Fetus business.industry Birth weight Doppler Twins Obstetrics and Gynecology Hemodynamics Aortic isthmus Blood flow computer.software_genre Logistic regression Maternal-Fetal Medicine Correlation Internal medicine Cardiology Medicine Chorionicity Original Article Data mining Analysis of variance business Prospective cohort study computer Growth discordance |
Zdroj: | Obstetrics & Gynecology Science |
ISSN: | 2287-8580 2287-8572 |
Popis: | OBJECTIVE The purpose of this study was to investigate the aortic isthmus (AoI) flow difference between larger fetus and smaller fetus of twin; and to evaluate the predictive value of early diagnosis of hemodynamic change in twin growth. METHODS This prospective study on 49 pairs of twin fetuses was performed to obtain AoI blood flow data. Cases with structural or chromosomal abnormalities and co-twin death were excluded. The interval from examination to delivery was within 4 weeks and 3 cases over 4 weeks interval were re-examined. Assessment of fetal AoI Doppler parameters were peak systolic velocity (PSV), end-diastolic velocity, times-averaged maximum velocities, pulsatility index (PI), and resistance index (RI). According to the direction of the diastolic flow in the AoI, antegrade and retrograde flow were made and was used to analyze the perinatal outcomes of each fetus. The predictive value of AoI Doppler parameters in predicting fetal growth was obtained by using ANOVA and logistic regression analysis of quantitative variables in each fetus of twins. RESULTS There were significant differences in the gestational weeks at delivery, birth weight and the incidence of growth discordance over 20% or more between monochorionic twin and dichorionic twin. The AoI PI and RI were significantly higher in smaller fetus than in larger regardless of chorionicity. Retrograde flow was noted in 8 of 98 cases (8.2%) and the only one case was of the larger fetus and the others were smaller fetuses of twin. Significant correlations were found between the AoI PI and birthweight (P=0.018) and between the PSV and growth discordance (P=0.032). In monochorionic twin, linear correlation was shown between the AoI PI and birthweight (P=0.004) and between AoI PI and growth discordance (P=0.031). Also, the meaningful correlation between the PSV and birthweight (P=0.036) was found by using logistic regression analyses. CONCLUSION On the basis of our observation, AoI PI has revealed their hemodynamic status and this result may improve the understanding of growth patterns in twins. |
Databáze: | OpenAIRE |
Externí odkaz: |