The value of noncontrast MRI in evaluating breast imaging reporting and data system category 0 lesions on digital mammograms
Autor: | Ruixin, Zhang, Maosheng, Xu, Changyu, Zhou, Xuewei, Ding, Huan, Lu, Min, Ge, Liang, Du, Yangyang, Bu |
---|---|
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | Quantitative Imaging in Medicine and Surgery. 12:4069-4080 |
ISSN: | 2223-4306 2223-4292 |
Popis: | Benign and malignant diagnosis of nonpalpable breast imaging reporting and data system (BI-RADS) category 0 lesions on digital mammograms (DMs) is very important. We compared the diagnostic performance of non-contrast-enhanced magnetic resonance imaging (MRI) and dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI) for them. We sought to evaluate BI-RADS category 0 lesions using 3 MRI sequences: short tau inversion recovery (STIR), STIR combined with high b value diffusion-weighted imaging (STIR-DWI), and DCE-MRI.We retrospectively reviewed 114 breast DMs rated as nonpalpable BI-RADS category 0 lesions in 112 patients from January 2014 to June 2019. STIR, high b value DWI, and DCE-MRI were performed for all patients. Two breast radiologists read individual sequences (STIR, DWI, DCE-MRI) and pairs of sequences (STIR-DWI) to detect BI-RADS category 0 lesions in DMs. Receiver operating characteristic (ROC) curve analysis was used to assess diagnostic performance according to a best valuable comparator that combined MRI imaging, clinical, and pathological data.Among of 114 lesions (the median age of patients was 47 years; the median size of the lesion was 19 mm), 32 (48.5%) malignant lesions were missed by STIR, 9 (13.6%) malignant lesions were missed by STIR-DWI, and 3 (4.5%) malignant lesions were missed by DCE-MRI. The principal finding of our study was that STIR-DWI and DCE-MRI showed higher diagnostic accuracy than did STIR (P0.01). STIR-DWI showed higher accuracy [area under the curve (AUC) =0.858; sensitivity =87.8%] for BI-RADS category 0 lesions in DMs than did STIR (AUC =0.754; sensitivity =51.5%), while the performance was comparable to that of DCE-MRI (AUC =0.884; sensitivity =95.5%).Using pairs of sequences (STIR-DWI) is a non-contrast-enhanced MRI technique and had an equal diagnostic performance in distinguishing benign from malignant lesions among nonpalpable BI-RADS category 0 lesions to that of DCE-MRI. As a result, STIR-DWI as having the potential to improve the safety and efficacy in of breast cancer screening, especially in nonpalpable BI-RADS category 0 lesions at in DMs. |
Databáze: | OpenAIRE |
Externí odkaz: |