Comparison of right-to-left shunt characteristics in cryptogenic embolic ischemic stroke and non-cardioembolic ischemic stroke
Autor: | Viviane Flumignan Zétola, Gabriel Pereira Braga, Valeria Cristina Scavasine, Jamileh Chamma, Rodrigo Bazan, Marcos Christiano Lange |
---|---|
Přispěvatelé: | Universidade Federal do Paraná (UFPR), Universidade Estadual Paulista (UNESP), Universidade Federal de Mato Grosso do Sul (UFMS) |
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
Ultrassonografia Doppler Transcraniana Ultrasonography Doppler Transcranial medicine.medical_treatment Right-to-left shunt Embolism Foramen Ovale Patent Neurosciences. Biological psychiatry. Neuropsychiatry Transcranial Brain Ischemia Foramen ovale Embolia Paradoxal Internal medicine medicine.artery medicine Valsalva maneuver Humans Paradoxical Stroke Ultrasonography Retrospective Studies Ischemic Stroke business.industry Doppler Retrospective cohort study AVC Isquêmico medicine.disease Transcranial Doppler Neurology Ischemic stroke Acidente Vascular Cerebral Cardiology Patent foramen ovale Forame Oval Patente Patent Neurology (clinical) business Shunt (electrical) Embolism Paradoxical RC321-571 |
Zdroj: | Arquivos de Neuro-Psiquiatria, Vol 79, Iss 10, Pp 859-863 (2021) Arquivos de Neuro-Psiquiatria, Volume: 79, Issue: 10, Pages: 859-863, Published: 2021 Arquivos de Neuro-Psiquiatria v.79 n.10 2021 Arquivos de neuro-psiquiatria Academia Brasileira de Neurologia instacron:ABNEURO Scopus Repositório Institucional da UNESP Universidade Estadual Paulista (UNESP) instacron:UNESP |
ISSN: | 1678-4227 |
Popis: | Background: Patent foramen ovale (PFO) has been considered a potential mechanism of embolic stroke of undetermined origin. Objective: The aim of the present study was to identify the features of the right-to-left shunt (RLS) in patients with undetermined embolic ischemic stroke and compare them with those of patients with non-cardioembolic ischemic stroke. Methods: A retrospective study was conducted with 168 patients with stroke and RLS separated into the following two groups: the undetermined embolic stroke group (UES group) and non-cardioembolic stroke group (NCES group). All patients were assessed by transcranial Doppler to evaluate the presence and quantification of microembolic signals (MES) at rest and under Valsalva maneuver. Results: Of all patients evaluated in the current study, 96 were included in the UES group and 72 in the NCES group. In the UES group, 65 patients had RLS with ≥10 MES (67.7%), which was higher than that observed in the NCES group (51.4%, p=0.038). According to the moment of the cardiac cycle, 75 patients (78.1%) in the UES group had a positive test at rest compared to 42 (58.3%) in the NCES group (p=0.007). Conclusions: The current study demonstrated that almost 70% of patients with undetermined embolic stroke and PFO presented a large RLS and more than 75% had RLS at rest. These findings suggest that the size of the shunt should be taken into account when evaluating whether PFO could be a possible mechanism underlying cryptogenic stroke. RESUMO Antecedentes: Uma das potenciais fontes embólicas no acidente vascular cerebral (AVC) de origem indeterminada é o forame oval patente (FOP). Objetivo: O objetivo do presente estudo foi identificar as características do shunt direita-esquerda em paciente com AVC de etiologia indeterminada, presumidamente embólica, e comparar tais características com pacientes apresentando AVC por outras causas não embólicas. Métodos: Trata-se de um estudo retrospectivo com 168 pacientes com AVC e forame oval patente, separados em dois grupos: AVC embólico de etiologia indeterminada e AVC por outras causas não embólicas. Todos os pacientes foram submetidos a Doppler transcraniano, para avaliar a presença de shunt direita-esquerda por meio do teste de embolia paradoxal. Além da quantificação de microbolhas, também foi avaliada a presença de shunt em repouso e sob manobra de Valsalva. Resultado: Do total, 96 pacientes foram incluídos no primeiro grupo (AVC indeterminado) e 72, no segundo grupo (AVC não embólico). No primeiro grupo, 65 pacientes exibiram shunt com passagem de mais de 10 microbolhas (67,5%), enquanto no segundo grupo isso aconteceu em 51,4% (p=0,038) dos casos. Além disso, 75 pacientes (78,1%) do primeiro grupo tiveram teste positivo ao repouso, comparados com 42 pacientes (58,3%) no segundo grupo (p=0,007). Conclusão: O presente estudo demonstrou que até 70% dos pacientes com AVC de etiologia indeterminada e forame oval apresentaram shunts maiores; em mais de 75%, houve passagem de microbolhas ao repouso. Esses achados sugerem que as características do shunt, como quantidade de microbolhas e passagem ao repouso, devem ser levadas em consideração na avaliação do FOP como possível mecanismo subjacente ao AVC. |
Databáze: | OpenAIRE |
Externí odkaz: |