Calibration of hip accelerometers for measuring physical activity and sedentary behaviours in adults with Down syndrome

Autor: S. Agiovlasitis, B. K. Ballenger, E. E. Schultz, Q. Du, R. W. Motl
Rok vydání: 2022
Předmět:
Zdroj: Journal of intellectual disability research : JIDRReferences.
ISSN: 1365-2788
Popis: The knowledge base on physical activity and sedentary behaviour in adults with Down syndrome (DS) may advance by accelerometer calibration studies. This study aimed to develop cut-points for sedentary behaviour and moderate-to-vigorous physical activity (MVPA) for adults with DS based on output from accelerometers worn on the dominant and non-dominant hips.Sixteen adults with DS (10 men; age 31 ± 15 years) performed 12 tasks including sedentary behaviours and physical activities. We obtained metabolic equivalents (METs) with indirect calorimetry and vector magnitude (VM) output from triaxial accelerometers (wGT3X-BT, ActiGraph) worn on the dominant and non-dominant hips. Receiver operating characteristic curves were used to identify optimal VM cut-points that maximised sensitivity and specificity.Overall classification accuracy was very high (area under the ROC curve: 0.95 and 0.92 for sedentary and MVPA models, respectively). For the non-dominant hip, the optimal VM cut-points were (1) sedentary behaviour ≤236 counts·minThe presented VM cut-points for sedentary behaviour and MVPA for adults with DS had high classification accuracy. There were small differences in accelerometer cut-points between the dominant and non-dominant hip.
Databáze: OpenAIRE