Pharmacokinetics of 99mTc-MAA- and 99mTc-HSA-Microspheres Used in Preradioembolization Dosimetry: Influence on the Liver–Lung Shunt

Autor: G Ulrich, Konrad Mohnike, Wolf Richter, Maciej Pech, Holger Amthauer, Philipp Genseke, Jens Ricke, Oliver S. Grosser, Annette Pethe, Dennis Kupitz, Juri Ruf
Rok vydání: 2016
Předmět:
Zdroj: Journal of Nuclear Medicine. 57:925-927
ISSN: 2159-662X
0161-5505
DOI: 10.2967/jnumed.115.169987
Popis: Perfusion scintigraphy using 99mTc-labeled albumin aggregates is mandatory before hepatic radioembolization with 90Y-microspheres. As part of a prospective trial, the intrahepatic and intrapulmonary stability of 2 albumin compounds, 99mTc-MAA (macroaggregated serum albumin [MAA]) and 99mTc-HSA (human serum albumin [HSA]), was assessed. Methods: In 24 patients with metastatic colorectal cancer, biodistribution (liver, lung) and liver–lung shunt (LLS) of both tracers (12 patients each) were assessed by sequential planar scintigraphy (1, 5, and 24 h after injection). Results: Liver uptake of both albumin compounds decreased differently. Although initial LLSs at 1 h after injection were similar in both groups, MAA-LLS increased significantly from 1 (3.9%) to 5 h (7.7%) and 24 h (9.9%) after injection, respectively. HSA-LLS did not change significantly (1 to 5 h), indicating a steady state of pulmonary and intrahepatic degradation. Conclusion: Compared with 99mTc-MAA-microspheres, 99mTc-HSA-microspheres are likely more resistant to degradation over time, allowing a reliable LLS determination even at later time points.