Occupational asthma caused by heated triglycidyl isocyanurate
Autor: | W. Anees, PS Burge, J. S. Croft, AS Robertson, Vicky Moore |
---|---|
Rok vydání: | 2010 |
Předmět: |
Adult
Male Hot Temperature Time Factors Peak flow measurement Bronchial provocation tests Antineoplastic Agents Peak Expiratory Flow Rate Bronchial Provocation Tests Specific inhalation challenge Occupational Exposure medicine Humans Asthma Triazines business.industry Public Health Environmental and Occupational Health Middle Aged medicine.disease Occupational Diseases Immunology Female Gases Occupational exposure Challenge tests business Occupational asthma Triglycidyl isocyanurate |
Zdroj: | Occupational Medicine. 61:65-67 |
ISSN: | 1471-8405 0962-7480 |
Popis: | Six workers exposed as bystanders to heated triglycidyl isocyanurate (TGIC) developed occupational asthma confirmed by serial peak expiratory flow measurement and Oasys analysis. Specific inhalation challenge testing resulted in late or dual asthmatic reactions to heated TGIC in four of four tested and was negative in three control asthmatics. One worker tested only with unheated TGIC had a negative specific challenge test. Heated TGIC can cause occupational asthma from bystander exposure. |