Lessons Learned from the Operation of a 70 Tonne per Day Post Combustion Pilot Plant at the Coal Fired Power Plant in Wilhelmshaven, Germany
Autor: | Joseph Yonkoski, Helmut Rode, Peter Radgen, Satish Reddy |
---|---|
Jazyk: | angličtina |
Předmět: |
Thermal Reclaimer
Aerosols Engineering Waste management business.industry Stress Corrosion Cracking Lab scale Lean Vapour Compressor Energy consumption Energy Consumption SO3 Post combustion Pilot Plant CCS Pilot plant Particles Energy(all) Emissions Coal Flue Gas business Tonne Post Combustion Reclaimer Coal fired power plant Efficient energy use |
Zdroj: | Energy Procedia. :1585-1594 |
ISSN: | 1876-6102 |
DOI: | 10.1016/j.egypro.2014.11.168 |
Popis: | The paper describes experimental results obtained with CO 2 capture from a coal fired power plant in Wilhelmshaven. After giving some basic information on the power and the pilot-scale carbon capture unit, findings on stress corrosion cracking in the Reclaimer, impact of SO3 on solvent emission and energy efficiency, which can be improved by applying lean vapour recompression. The paper highlight the learnings achieved when moving from lab scale testing to pilot scale testing. |
Databáze: | OpenAIRE |
Externí odkaz: |