Effects of cold recovery technology on the microbial drinking water quality in unchlorinated distribution systems
Autor: | Jawairia Imtiaz Ahmad, Paul W. J. J. van der Wielen, Gang Liu, Jan Peter van der Hoek, Gertjan Medema |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: |
Opportunistic pathogens
010501 environmental sciences 01 natural sciences Biochemistry Distribution system Microbial ecology 03 medical and health sciences 0302 clinical medicine Water Supply Water Quality Heat exchanger 030212 general & internal medicine Food science Temperature difference MolEco Relative species abundance 0105 earth and related environmental sciences General Environmental Science Bacteria Drinking Water Biofilm Drinking water distribution system Microbiological quality Drinking water quality Cold recovery Cold Temperature Microbial population biology Biofilms Environmental science Water quality Bacterial community Water Microbiology |
Zdroj: | Environmental Research, 183 Environmental Research 183 (2020) |
ISSN: | 0013-9351 |
Popis: | Drinking water distribution systems (DWDSs) are used to supply hygienically safe and biologically stable water for human consumption. The potential of thermal energy recovery from drinking water has been explored recently to provide cooling for buildings. Yet, the effects of increased water temperature induced by this “cold recovery” on the water quality in DWDSs are not known. The objective of this study was to investigate the impact of cold recovery from DWDSs on the microbiological quality of drinking water. For this purpose, three pilot distribution systems were operated in parallel for 38 weeks. System 1 has an operational heat exchanger, mimicking the cold recovery system by maintaining the water temperature at 25 °C; system 2 operated with a non-operational heat exchanger and system 3 run without heat exchanger. The results showed no significant effects on drinking water quality: cell numbers and ATP concentrations remained around 3.5 × 105 cells/ml and 4 ng ATP/l, comparable observed operational taxonomic units (OTUs) (~470–490) and similar Shannon indices (7.7–8.9). In the system with cold recovery, a higher relative abundance of Pseudomonas spp. and Chryseobacterium spp. was observed in the drinking water microbial community, but only when the cold recovery induced temperature difference (ΔT) was higher than 9 °C. In the 38 weeks’ old biofilm, higher ATP concentration (475 vs. 89 pg/cm2), lower diversity (observed OTUs: 88 vs. ≥200) and a different bacterial community composition (e.g. higher relative abundance of Novosphingobium spp.) were detected, which did not influence water quality. No impacts were observed for the selected opportunisitic pathogens after introducing cold recovery. It is concluded that cold recovery does not affect bacterial water quality. Further investigation for a longer period is commended to understand the dynamic responses of biofilm to the increased temperature caused by cold recovery. |
Databáze: | OpenAIRE |
Externí odkaz: |