QuEChERS extraction for multi-residue analysis of PCBs, PAHs, PBDEs and PCDD/Fs in biological samples

Autor: Mélanie Desrosiers, Pauline Brousseau, Paule Emilie Groleau, Michel Fournier, Frédérik Fortin, Pierre-Luc Cloutier
Přispěvatelé: Institut Armand Frappier (INRS-IAF), Réseau International des Instituts Pasteur (RIIP)-Institut National de la Recherche Scientifique [Québec] (INRS), Centre d'expertise en analyse environnementale du Québec
Rok vydání: 2016
Předmět:
[SDV.BIO]Life Sciences [q-bio]/Biotechnology
Polychlorinated Dibenzodioxins
Polybrominated diphenyl ethers (PBDEs)
Mytilus edulis
[SDV]Life Sciences [q-bio]
Salmo salar
Gel permeation chromatography (GPC)
Cheap
010501 environmental sciences
Quechers
01 natural sciences
Gas Chromatography-Mass Spectrometry
Analytical Chemistry
Gel permeation chromatography
Halogenated Diphenyl Ethers
media_common.cataloged_instance
Animals
Easy
Solid phase extraction
European union
Polycyclic Aromatic Hydrocarbons
Environmental biomonitoring
0105 earth and related environmental sciences
media_common
Benzofurans
Detection limit
Polychlorinated biphenyls (PCBs)
Chemistry
010401 analytical chemistry
Extraction (chemistry)
Solid Phase Extraction
Polychlorinated dibenzodioxins and dibenzofurans (PCDD/Fs)
Lipids
Polychlorinated Biphenyls
0104 chemical sciences
Efficient
Certified reference materials
Polycyclic aromatic hydrocarbons (PAHs)
[SHS.ENVIR]Humanities and Social Sciences/Environmental studies
Environmental chemistry
Chromatography
Gel

Rugged and Safe (QuEChERS)
Environmental Pollutants
Gas chromatography
Quick
Environmental Monitoring
Zdroj: Talanta
Talanta, Elsevier, 2017, 165, pp.332-338. ⟨10.1016/j.talanta.2016.12.080⟩
ISSN: 1873-3573
0039-9140
DOI: 10.1016/j.talanta.2016.12.080⟩
Popis: International audience; In this study, a fast and rugged method is presented for the analysis of PCBs, PAHs, PBDEs and PCDD/Fs in biological tissues using a simple Quick, Easy, Cheap, Efficient, Rugged and Safe (QuEChERS) extraction and a clean-up by Gel Permeation Chromatography (GPC) and silica Solid Phase Extraction (SPE). Development was performed on blue mussels (Mytilus edulis) and Atlantic salmon (Salmo salar) for evaluation of two ranges of lipid and water content of biological tissues. Statistical validation was performed with Atlantic salmon samples. Forty-five PAHs were analyzed including the priority list of the US EPA and the European Union with 41 PCBs, 24 PBDEs and 17 PCDD/Fs. Instrumental analyses were performed on Gas Chromatography - High Resolution Mass Spectrometry (GC-HRMS). Accuracy was evaluated for PCBs and PCDD/Fs with a certified reference material furnished by the National Research Council Canada (NRCC) and also compared with results obtained by the conventional Soxhlet extraction. Statistical validation showed recoveries for PCBs, PAHs, PBDEs and PCDD/Fs close to 100% with average Relative Standard Deviation (RSD) lower than 10% and internal standard recoveries in the range of 70% with average RSD ranging from 5-15%. Average calculated Method Detection Limits (MDLs) were lower than 0.05μg/Kg for PCBs, 0.2μg/Kg for PAHs and PBDEs and 1ng/Kg for PCDD/Fs. The method is a faster and cheaper alternative to the time-consuming conventional method that has been used in most environmental laboratories.
Databáze: OpenAIRE