Near-infrared Fourier transform room-temperature photoluminescence of erbium complexes
Autor: | Pascal Fias, Laurent Divay, E. Lallier, R. Van Deun, J. Barbillat, P. Le Barny, A. Grisard |
---|---|
Přispěvatelé: | Laboratoire Avancé de Spectroscopie pour les Intéractions la Réactivité et l'Environnement - UMR 8516 (LASIRE), Institut de Chimie du CNRS (INC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS)-Centrale Lille Institut (CLIL), Thales Research and Technologies [Orsay] (TRT), THALES, Department of Chemistry, Coordination Chemistry Division, Catholic University of Leuven - Katholieke Universiteit Leuven (KU Leuven), Institut de Chimie du CNRS (INC)-Université de Lille-Centre National de la Recherche Scientifique (CNRS), THALES [France] |
Rok vydání: | 2003 |
Předmět: |
Lanthanide
Technology and Engineering Photoluminescence Materials science Phenanthroline Analytical chemistry Infrared spectroscopy chemistry.chemical_element 02 engineering and technology 010402 general chemistry 7. Clean energy 01 natural sciences Erbium chemistry.chemical_compound symbols.namesake AMPLIFIERS ELECTROLUMINESCENCE Spectroscopy Instrumentation business.industry 021001 nanoscience & nanotechnology 0104 chemical sciences chemistry symbols Optoelectronics Light emission 0210 nano-technology business Raman spectroscopy |
Zdroj: | REVIEW OF SCIENTIFIC INSTRUMENTS Review of Scientific Instruments Review of Scientific Instruments, American Institute of Physics, 2003, 74, pp.4954-4957. ⟨10.1063/1.1614873⟩ Review of Scientific Instruments, 2003, 74, pp.4954-4957. ⟨10.1063/1.1614873⟩ |
ISSN: | 1089-7623 0034-6748 |
Popis: | A modified Fourier transform (FT) Raman bench spectrometer designed for the detection of weak light emission in the 800–1700 nm wavelength region has been used to demonstrate the advantages of FT spectroscopy for measuring near-infrared photoluminescence spectra of lanthanide complexes with a good resolution and very good sensitivity. This apparatus has been tested with an ultraviolet laser source (325 nm) on three standard erbium complexes. The 4I13/24I15/2 emission of tris-(acetylacetonato) (1,10 phenanthroline) erbium [Er(acac)3(phen)], tris-(4,4,4,-trifluoro-1-(2 thenoyl)-1,3-butenedione) (1,10 phenanthroline) erbium [Er(TTFA)3(phen)] and tris(8-hydroxyquinolinato) erbium [Erq3] has thus been recorded in solution and in the solid state and compared with literature. ©2003 American Institute of Physics. |
Databáze: | OpenAIRE |