Analyzing Femorotibial Cartilage Thickness Using Anatomically Standardized Maps: Reproducibility and Reference Data
Autor: | Alessandro Cavinato, Julien Favre, H. Babel, Brigitte M. Jolles, Katerina Blazek, Thomas P. Andriacchi |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Reference data (financial markets)
lcsh:Medicine High resolution knee Osteoarthritis pattern Article 030218 nuclear medicine & medical imaging 03 medical and health sciences 0302 clinical medicine registration morphology Medicine cartilage 030203 arthritis & rheumatology Reproducibility medicine.diagnostic_test business.industry Cartilage lcsh:R osteoarthritis Magnetic resonance imaging General Medicine Cartilage thickness medicine.disease Computational anatomy medicine.anatomical_structure business Biomedical engineering |
Zdroj: | Journal of Clinical Medicine Volume 10 Issue 3 Journal of clinical medicine, vol. 10, no. 3, pp. 461 Journal of Clinical Medicine, Vol 10, Iss 461, p 461 (2021) |
ISSN: | 2077-0383 |
DOI: | 10.3390/jcm10030461 |
Popis: | Alterations in cartilage thickness (CTh) are a hallmark of knee osteoarthritis, which remain difficult to characterize at high resolution, even with modern magnetic resonance imaging (MRI), due to a paucity of standardization tools. This study aimed to assess a computational anatomy method producing standardized two-dimensional femorotibial CTh maps. The method was assessed with twenty knees, processed following three common experimental scenarios. Cartilage thickness maps were obtained for the femorotibial cartilages by reconstructing bone and cartilage mesh models in tree-dimension, calculating three-dimensional CTh maps, and anatomically standardizing the maps. The intra-operator accuracy (median (interquartile range, IQR) of &minus 0.006 (0.045) mm), precision (0.152 (0.070) mm), entropy (7.02 (0.71) and agreement (0.975 (0.020))) results suggested that the method is adequate to capture the spatial variations in CTh and compare knees at varying osteoarthritis stages. The lower inter-operator precision (0.496 (0.132) mm) and agreement (0.808 (0.108)) indicate a possible loss of sensitivity to detect differences in a setting with multiple operators. The results confirmed the promising potential of anatomically standardized maps, with the lower inter-operator reproducibility stressing the need to coordinate operators. This study also provided essential reference data and indications for future research using CTh maps. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |