Performance of 11C-Pittsburgh Compound B PET Binding Potential Images in the Detection of Amyloid Deposits on Equivocal Static Images

Autor: Chisa Hosokawa, Yuichi Kimura, Kenji Shimamoto, Kenta Sakaguchi, Kimio Usami, Yuzuru Yamazoe, Takamichi Murakami, Tomoko Hyodo, Makoto Hosono, Kazunari Ishii
Rok vydání: 2015
Předmět:
Zdroj: Journal of Nuclear Medicine. 56:1910-1915
ISSN: 2159-662X
0161-5505
DOI: 10.2967/jnumed.115.156414
Popis: The goal of this study was to clarify whether binding potential (BP) images using (11)C-Pittsburgh compound B ((11)C-PiB) and dynamic PET can reliably detect cortical amyloid deposits for patients whose (11)C-PiB PET static images are ambiguous and whether visual ratings are affected by white matter retention.Static and BP images were constructed for 85 consecutive patients with cognitive impairment after (11)C-PiB dynamic PET. Cortical uptake was visually assessed as positive, negative, or equivocal for both types of images. Quantitatively, the standardized uptake value ratio (SUVR) from the static image, the nondisplaceable BP from the dynamic image for mean gray matter uptake, and the ratio of gray matter uptake to white matter retention were compared among (11)C-PiB-positive, (11)C-PiB-equivocal, and (11)C-PiB-negative groups.Forty-three scans were visually assessed as (11)C-PiB-positive in both the static and the BP images. Ten scans were (11)C-PiB-equivocal in the static images. In 8 of them, the BP images were (11)C-PiB-positive, whereas the other 2 were (11)C-PiB-equivocal. Thirty-two scans were assessed as (11)C-PiB-negative in the static images. In the BP images, 4 were (11)C-PiB-positive and 2 were (11)C-PiB-equivocal. The mean gray matter uptake of (11)C-PiB in SUVR and nondisplaceable BP, respectively, showed statistically significant differences among the (11)C-PiB-positive, (11)C-PiB-equivocal, and (11)C-PiB-negative groups. The ratio of gray matter uptake to white matter retention was lower in the BP images than static images from the (11)C-PiB-negative and (11)C-PiB-equivocal groups, whereas it was higher in the (11)C-PiB-positive group.(11)C-PiB PET BP images can clarify visual interpretation of clinical static (11)C-PiB-equivocal images by reducing the interference of nonspecific white matter retention. We conclude that (11)C-PiB-equivocal PET findings on static images reflect cortical amyloid deposits, which can be verified using BP images. Furthermore, quantitative assessments, such as SUVR and nondisplaceable BP, are of no use for correctly rating equivocal visual findings.
Databáze: OpenAIRE