Synthetic modification of PAN membrane: biocompatibility and functional characterization
Autor: | Karel Opatrny, Hans J. Gurland, H. Hacker, B. Schmidt, Salim Mujais |
---|---|
Rok vydání: | 1995 |
Předmět: |
Adult
Biocompatibility Adolescent Bradykinin Biocompatible Materials Complement C5a Complement Membrane Attack Complex chemistry.chemical_compound Leukocyte Count Renal Dialysis Medicine Humans Urea Aged Transplantation Creatinine biology business.industry Beta-2 microglobulin Thrombin Angiotensin-converting enzyme Membranes Artificial Middle Aged Membrane chemistry Biochemistry Nephrology Biophysics biology.protein Kidney Failure Chronic Complement membrane attack complex business beta 2-Microglobulin |
Zdroj: | Nephrology, dialysis, transplantation : official publication of the European Dialysis and Transplant Association - European Renal Association. 10 |
ISSN: | 0931-0509 |
Popis: | A disturbing interaction of PAN membranes and the bradykinin generation system particularly in the presence of angiotensin converting enzyme inhibitors has been described. A modified new membrane, SPAN (special PAN), was produced by varying the polymer components in type and composition, in particular by a reduction in Na-Methallylsulfonate. Although the SPAN membrane successfully averted the bradykinin generating ability of PAN, it was important to determine whether such a modification did not lead to a loss of the satisfactory biocompatibility profile characteristic of the parent membrane. For this purpose, we conducted the present clinical study in nine patients comparing 3 membranes ; (i) a polysulphone membrane (F60S) ; (ii) PAN ; and (iii) SPAN, to examine the clinical biocompatibility profile and performance of the new membrane. A small increase in C5a with F60S and SPAN was found which is in the range expected for highly biocompatible synthetic membranes. The three dialysers had a similar inert profile for terminal complement complex arterial values, and had similar venous values. A minimal non-significant decline in white cell count was observed at 15 min for all dialysers, but otherwise WBC counts were unchanged. Platelet counts were unchanged throughout treatment for the three dialysers. Arterial and venous thrombin-anti-thrombin complex values were similar for all three dialysers. F60S and SPAN dialysers had similar urea clearances. PAN urea clearance was slightly lower than the other two dialysers. The results with creatinine clearances were similar to those of urea. β 2 Microglobulin clearance was substantial for F60S dialysers. SPAN dialysers had a significant β 2 microglobulin clearance that was slightly less than F60S. PAN dialysers had minimal clearance for this molecule at the time points studied. In summary, the results of the present study indicate that the synthetic modification of PAN to abrogate its bradykinin generating effect did not adversely affect its biocompatibility profile and that the new membrane behaves in the range typical of its synthetic congeners. |
Databáze: | OpenAIRE |
Externí odkaz: |