Avoiding a Wrapped Endotracheal Tube in Laser Laryngeal Surgery

Autor: Donald B. Hawkins, Mary M. Joseph
Rok vydání: 1990
Předmět:
Zdroj: The Laryngoscope. 100:1283
ISSN: 0023-852X
DOI: 10.1288/00005537-199012000-00006
Popis: Ninety-one laser laryngeal procedures using the apneic technique of anesthesia were performed in 28 patients between 2 months and 64 years of age. Seventy-two procedures (79%) were performed on children and 19 on adults. There were no complications. Eight laser laryngoscopies were performed using a new metal Laser-Flex® endotracheal tube. Obstruction of the endotracheal tube with a mucous plug occurred in one case. The apneic technique described in this paper provides a laser operative field free of an endotracheal tube, virtually eliminating the danger of a laser fire. It is a relatively safe and effective means of performing laser laryngeal surgery. In addition, the Laser-Flex endotracheal tube appears to be an acceptable alternative to a metallic tape-wrapped endotracheal tube.
Databáze: OpenAIRE