425. The Utility of Paired Upper and Lower COVID-19 Sampling in Patients with Artificial Airways
Autor: | Eimear Kitt, Julia S Sammons, Kathleen Chiotos, Susan E Coffin, Allison Ballantine, Elizabeth Gallagher, Coralee DelValle Mojica, Kevin P O’Callaghan, Caryn Kerman, Rebecca Harris, Louis Bell, Daniela Davis, Ellen Nord |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2020 |
Předmět: |
Mechanical ventilation
medicine.medical_specialty Coronavirus disease 2019 (COVID-19) business.industry Severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) medicine.medical_treatment Concordance Artificial Airways Infectious Diseases AcademicSubjects/MED00290 Paired samples Oncology Internal medicine Poster Abstracts Medicine In patient Sampling (medicine) business |
Zdroj: | Open Forum Infectious Diseases |
ISSN: | 2328-8957 |
Popis: | Background The Centers for Disease Control and Prevention (CDC) recommends upper respiratory tract (URT) polymerase chain reaction (PCR) testing as the initial diagnostic test for Severe Acute Respiratory Syndrome Coronavirus-2 (SARS-CoV-2). Lower respiratory tract (LRT) testing for patients requiring mechanical ventilation is also recommended. The goal of this study was to evaluate concordance between paired URT and LRT specimens in children undergoing pre-admission/procedure screening or diagnostic testing. We hypothesized that < 10% of paired tests would have discordant results. Methods Single center cross-sectional study including children with artificial airways who had paired URT and LRT SARS-CoV-2 PCR testing between 4/1/2020 and 6/8/2020. URT specimens included nasopharyngeal (NP) swabs and aspirates. LRT specimens included tracheal aspirates and bronchoalveolar lavages. URT and LRT specimens were classified as paired if the two specimens were collected within 24 hours. Artificial airways included tracheostomies and endotracheal tubes. Tests were classified as diagnostic versus screening based on the indication selected in the order. Results 102 paired specimens were obtained during the study period. Fifty-nine were performed for screening and 43 were performed for diagnosis of suspected SARS-CoV-2. Overall, 94 specimens (92%) were concordant, including 89 negative from both sources and 5 positive from both sources. Eight specimens (8%) were discordant, all of which were positive from the URT and negative from the LRT (Figure 1). Among patients undergoing screening, 3 of 4 positive tests were discordant and among symptomatic patients, 5 of 9 positive tests were discordant. There were no instances of a positive LRT specimen with a negative URT specimen. Figure 1. Performance of upper and lower respiratory tract SARS-CoV-2 PCR testing in children with artificial airways Conclusion Overall, most paired samples from the URT and LRT yielded concordant results with no pairs positive from the LRT and negative from the URT. These data support the CDC recommendation that URT specimens are the preferred initial SARS-CoV-2 test, while LRT specimens should be collected only from mechanically ventilated with suspected SARS-CoV-2. Disclosures All Authors: No reported disclosures |
Databáze: | OpenAIRE |
Externí odkaz: |