A Novel Guided Zygomatic and Pterygoid Implant Surgery System: A Human Cadaver Study on Accuracy
Autor: | Massimo Del Fabbro, Francesco Grecchi, Emma Grecchi, Ziv Mazor, Fabrizio Grivetto, Luigi V Stefanelli, Funda Goker, Nicola Pranno, Alessio Franchina, Rami Siev, Vittorio Di Lucia, Francesca De Angelis |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
guided surgery
CAD/CAM accuracy computer aided implantology dynamic navigation guidance navigation pterygoid implants surgical guides surgical templates zygomatic implant cadaver computer-aided design humans prostheses and implants tomography x-ray computed surgery computer-assisted Health Toxicology and Mutagenesis tomography Implant surgery Article System a surgery 03 medical and health sciences 0302 clinical medicine Cadaver Medicine Humans x-ray computed Human cadaver 030505 public health business.industry Public Health Environmental and Occupational Health 030206 dentistry Prostheses and Implants Implant placement Angular deviation Surgery Computer-Assisted computer-assisted Sintered titanium Computer-Aided Design Implant Keywords: CAD/CAM 0305 other medical science Nuclear medicine business Tomography X-Ray Computed |
Zdroj: | International Journal of Environmental Research and Public Health Volume 18 Issue 11 International Journal of Environmental Research and Public Health, Vol 18, Iss 6142, p 6142 (2021) |
ISSN: | 1660-4601 |
DOI: | 10.3390/ijerph18116142 |
Popis: | The aim of this human cadaver study was to assess the accuracy of zygomatic/pterygoid implant placement using custom-made bone-supported laser sintered titanium templates. For this purpose, pre-surgical planning was done on computed tomography scans of each cadaver. Surgical guides were printed using direct metal laser sintering technology. Four zygomatic and two pterygoid implants were inserted in each case using the guided protocol and related tools. Post-operative computed tomography (CT) scans were obtained to evaluate deviations between the planned and inserted implants. Accuracy was measured by overlaying the real position in the post-operative CT on the virtual presurgical placement of the implant in a CT image. Descriptive and bivariate analyses of the data were performed. As a result, a total of 40 zygomatic and 20 pterygoid implants were inserted in 10 cadavers. The mean deviations between the planned and the placed zygomatic and pterygoid implants were respectively (mean ± SD): 1.69° ± 1.12° and 4.15° ± 3.53° for angular deviation. Linear distance deviations: 0.93 mm ± 1.23 mm and 1.35 mm ± 1.45 mm at platform depth, 1.35 mm ± 0.78 mm and 1.81 mm ± 1.47 mm at apical plane, 1.07 mm ± 1.47 mm and 1.22 mm ± 1.44 mm for apical depth. In conclusion, the surgical guide system showed accuracy for all the variables studied and allowed acceptable and accurate implant placement regardless of the case complexity. |
Databáze: | OpenAIRE |
Externí odkaz: |