Accuracy of five intraocular lens formulas in eyes with trifocal lens implant
Autor: | Adriana Stănilă, Bogdana Tăbăcaru, Simona Stanca, C Danielescu, Horia Tudor Stanca, Monica Mălăescu |
---|---|
Rok vydání: | 2020 |
Předmět: |
0301 basic medicine
Cancer Research medicine.medical_specialty multifocal medicine.medical_treatment Statistical difference Intraocular lens 03 medical and health sciences 0302 clinical medicine Optical biometry Immunology and Microbiology (miscellaneous) Ophthalmology medicine hydrophobic trifocal Mathematics PanOptix Lens implant Anova test Articles intraocular lens formulas General Medicine Presbyopia medicine.disease Alcon Laboratories 030104 developmental biology 030220 oncology & carcinogenesis presbyopia Multifocal IOLs optical biometry |
Zdroj: | Experimental and Therapeutic Medicine |
ISSN: | 1792-0981 |
Popis: | Accuracy of intraocular lens (IOL) calculation formulas SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II were compared in prediction of postoperative refraction for multifocal and implants using a single optical biometry device. The authors included 88 refractive lens exchange and cataract surgeries, with AcrySof IQ PanOptix implant (Alcon Laboratories, Inc.). All eyes were divided into three groups based on axial length (AL), group 1: 24.5 mm (6 eyes). The refractive prediction error (RPE) and mean absolute error (MAE) were calculated for 5 different formulas: SRK/T, Hoffer Q, Holladay 1, Haigis and Barrett Universal II. For eyes with the AL between 22 mm and 24.5 mm the greatest percentage of eyes with RPEs within ±0.25 D was 32.4% for Haigis formula, followed by Barrett Universal II, Hoffer Q and Holladay 1 with 29.4%. The percentage of eyes with RPEs within ±0.50 D was 100% only for Barrett Universal II and Holladay 1, 94.1% for SRK/T and 91.2% for Haigis and Hoffer Q. The first and third group with AL 24.5 mm were too small to have statistical significance due to the reluctancy to use multifocal IOLs on extreme ALs. ANOVA test showed no statistical difference (P=0.166) between the RPEs measured for each formula in this cohort. This study showed no statistical difference between formulas for this trifocal lens implant. There was a tendency for the RPE to be within ±0.25 D for most of the eyes with the Haigis formula, and within ±0.50 D for all the eyes with the Barrett Universal II formula in the group with the AL between 22 and 24.5 mm. |
Databáze: | OpenAIRE |
Externí odkaz: | |
Nepřihlášeným uživatelům se plný text nezobrazuje | K zobrazení výsledku je třeba se přihlásit. |