Comparing Two-Zone Models of Dust Exposure
Autor: | Catherine E. Simmons, Fred W. Boelter, Rachael M. Jones |
---|---|
Rok vydání: | 2011 |
Předmět: |
Work (thermodynamics)
Mathematical model Meteorology Field (physics) Construction Materials Public Health Environmental and Occupational Health Dust Air Pollutants Occupational Models Theoretical Atmospheric sciences Respirable dust Joint compound Event data Occupational Exposure Range (statistics) Humans Environmental science Dust exposure |
Zdroj: | Journal of Occupational and Environmental Hygiene. 8:513-519 |
ISSN: | 1545-9632 1545-9624 |
DOI: | 10.1080/15459624.2011.598762 |
Popis: | The selection and application of mathematical models to work tasks is challenging. Previously, we developed and evaluated a semi-empirical two-zone model that predicts time-weighted average (TWA) concentrations (Ctwa) of dust emitted during the sanding of drywall joint compound. Here, we fit the emission rate and random air speed variables of a mechanistic two-zone model to testing event data and apply and evaluate the model using data from two field studies. We found that the fitted random air speed values and emission rate were sensitive to (i) the size of the near-field and (ii) the objective function used for fitting, but this did not substantially impact predicted dust Ctwa. The mechanistic model predictions were lower than the semi-empirical model predictions and measured respirable dust Ctwa at Site A but were within an acceptable range. At Site B, a 10.5 m3 room, the mechanistic model did not capture the observed difference between PBZ and area Ctwa. The model predicted uniform mixing and predicted dust Ctwa up to an order of magnitude greater than was measured. We suggest that applications of the mechanistic model be limited to contexts where the near-field volume is very small relative to the far-field volume. |
Databáze: | OpenAIRE |
Externí odkaz: |