Effects of Prosthetic Socket Design on Residual Femur Motion Using Dynamic Stereo X-Ray - A Preliminary Analysis
Autor: | J. Peter Loan, Susan E. D’Andrea, Jason Maikos, John M. Chomack, Kathryn M. Bradley |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
Orthodontics
Histology Computer science biplanar videoradiography Biomedical Engineering Bioengineering and Biotechnology Bioengineering transfemoral amputation Kinematics Prosthetic socket Brief Research Report socket kinematics Residual Compression (physics) equipment and supplies Motion (physics) Dynamic load testing residual limb body regions dynamic stereo x-ray Femur prosthetics Residual limb TP248.13-248.65 Biotechnology |
Zdroj: | Frontiers in Bioengineering and Biotechnology Frontiers in Bioengineering and Biotechnology, Vol 9 (2021) |
ISSN: | 2296-4185 |
Popis: | Individuals with transfemoral amputation experience relative motion between their residual limb and prosthetic socket, which can cause inefficient dynamic load transmission and secondary comorbidities that limit mobility. Accurately measuring the relative position and orientation of the residual limb relative to the prosthetic socket during dynamic activities can provide great insight into the complex mechanics of the socket/limb interface. Five participants with transfemoral amputation were recruited for this study. All participants had a well-fitting, ischial containment socket and were also fit with a compression/release stabilization socket. Participants underwent an 8-wk, randomized crossover trial to compare differences between socket types. Dynamic stereo x-ray was used to quantify three-dimensional residual bone kinematics relative to the prosthetic socket during treadmill walking at self-selected speed. Comfort, satisfaction, and utility were also assessed. There were no significant differences in relative femur kinematics between socket types in the three rotational degrees of freedom, as well as anterior-posterior and medial-lateral translation (p > 0.05). The ischial containment socket demonstrated significantly less proximal-distal translation (pistoning) of the femur compared to the compression/release stabilization socket during the gait cycle (p < 0.05), suggesting that the compression/release stabilization socket provided less control of the residual femur during distal translation. No significant differences in comfort and utility were found between socket types (p > 0.05). The quantitative, dynamic analytical tools used in the study were sensitive to distinguish differences in three-dimensional residual femur motion between two socket types, which can serve as a platform for future comparative effectiveness studies of socket technology. |
Databáze: | OpenAIRE |
Externí odkaz: |