Variability of the VA interval at tachycardia induction: a simple method to differentiate orthodromic reciprocating tachycardia from atypical atrioventricular nodal reentrant tachycardia
Autor: | Claudio Hadid, Leonardo Celano, Darío Di Toro, Edgar Antezana-Chavez, Sebastián Gallino, Gustavo Iralde, David Calvo, Pablo Ávila, Leonardo Atea, Sergio Gonzalez, Sebastián Maldonado, Carlos Labadet |
---|---|
Rok vydání: | 2022 |
Předmět: | |
Zdroj: | Journal of Interventional Cardiac Electrophysiology. |
ISSN: | 1572-8595 1383-875X |
DOI: | 10.1007/s10840-022-01376-w |
Popis: | The differential diagnosis between orthodromic atrioventricular reentry tachycardia (AVRT) and atypical AV nodal reentrant tachycardia (aAVNRT) is sometimes challenging. We hypothesize that aAVNRTs have more variability in the retrograde conduction time at tachycardia onset than AVRTs.We aimed to assess the variability in retrograde conduction time at tachycardia onset in AVRT and aAVNRT and to propose a new diagnostic tool to differentiate these two arrhythmia mechanisms. We measured the VA interval of the first beats after tachycardia induction until it stabilized. The difference between the maximum and minimum VA intervals (∆VA) and the number of beats needed for the VA interval to stabilize was analyzed. Atrial tachycardias were excluded.A total of 107 patients with aAVNRT (n = 37) or AVRT (n = 64) were included. Six additional patients with decremental accessory pathway-mediated tachycardia (DAPT) were analyzed separately. All aAVNRTs had VA interval variability. The median ∆VA was 0 (0 - 5) ms in AVRTs vs 40 (21 - 55) ms in aAVNRTs (p 0.001). The VA interval stabilized significantly earlier in AVRTs (median 1.5 [1 - 3] beats) than in aAVNRTs (5 [4 - 7] beats; p 0.001). A ∆VA 10 ms accurately differentiated AVRT from aAVNRT with 100% of sensitivity, specificity, and positive and negative predictive values. The stabilization of the VA interval at 3 beats of the tachycardia onset identified AVRT with sensitivity, specificity, and positive and negative predictive values of 64.1%, 94.6%, 95.3%, and 60.3%, respectively. A ∆VA 20 ms yielded good diagnostic accuracy for DAPT.A ∆VA 10 ms is a simple and useful criterion that accurately distinguished AVRT from atypical AVNRT. Central panel: Scatter plot showing individual values of ∆VA in atypical AVNRT and AVRT. Left panel: induction of atypical AVNRT. The VA interval stabilizes at the 5th beat and the ∆VA is 62 ms (maximum VA interval: 172 ms - minimum VA interval: 110 ms). Right panel: induction of AVRT. The tachycardia has a fixed VA interval from the first beat. ∆VA is 0 ms. |
Databáze: | OpenAIRE |
Externí odkaz: |