M-mode Diagnosis of Tachyarrhythmia Can be Erroneous Owing to 'Pseudo 1:1 Atrioventricular Movement' of the Atrial Wall Adjacent to the Atrioventricular Valve Possibly due to Atrioventricular Constraint: A Case of Neonatal Atrial Flutter With 2:1 Atrioventricular Conduction

Autor: Akio Ishiguro, Ayumi Oshima, Hideaki Senzaki, Mio Taketazu, Satoshi Masutani, Akiko Kawano, Hirotaka Ishido, Yoichi Iwamoto
Jazyk: angličtina
Rok vydání: 2018
Předmět:
Zdroj: Clinical Medicine Insights. Cardiology
Clinical Medicine Insights: Cardiology, Vol 12 (2018)
ISSN: 1179-5468
Popis: M-mode echocardiography has been playing an important role in the diagnosis of fetal tachyarrhythmia. We recently encountered a neonatal case of atrial flutter with 2:1 atrioventricular conduction. However, M-mode erroneously indicated 1:1 atrioventricular movement. While the movement of the atrial wall far from the atrioventricular valve was much faster than that of the ventricular wall, the atrial wall adjacent to the atrioventricular valve fully synchronized to that of the ventricular wall. Thus, to avoid this novel pitfall, it would be important to add an additional assessment focusing on the movement of the atrial wall far from the ventricle.