Optimization of inhomogeneous magnetization transfer (ihMT) MRI contrast for preclinical studies using dipolar relaxation time (T1D) filtering
Autor: | David C. Alsop, Gopal Varma, Guillaume Duhamel, Valentin H. Prevost, Samira Mchinda, Olivier M. Girard |
---|---|
Přispěvatelé: | Centre de résonance magnétique biologique et médicale (CRMBM), Aix Marseille Université (AMU)-Assistance Publique - Hôpitaux de Marseille (APHM)-Centre National de la Recherche Scientifique (CNRS), Beth Israel Deaconess - Harvard Medical School, ANR-11-IDEX-0001,Amidex,INITIATIVE D'EXCELLENCE AIX MARSEILLE UNIVERSITE(2011) |
Rok vydání: | 2017 |
Předmět: |
Materials science
[SDV.IB.IMA]Life Sciences [q-bio]/Bioengineering/Imaging ihMT Signal 030218 nuclear medicine & medical imaging Magnetic field Power (physics) White matter 03 medical and health sciences 0302 clinical medicine Nuclear magnetic resonance medicine.anatomical_structure crmbm [INFO.INFO-IM]Computer Science [cs]/Medical Imaging medicine Molecular Medicine Frequency offset Radiology Nuclear Medicine and imaging snc Magnetization transfer Sensitivity (control systems) Saturation (chemistry) ComputingMilieux_MISCELLANEOUS 030217 neurology & neurosurgery Spectroscopy |
Zdroj: | NMR in Biomedicine NMR in Biomedicine, 2017, 30 (6), ⟨10.1002/nbm.3706⟩ NMR in Biomedicine, Wiley, 2017, 30 (6), ⟨10.1002/nbm.3706⟩ |
ISSN: | 0952-3480 1099-1492 |
Popis: | International audience; A pulsed inhomogeneous magnetization transfer (ihMT)-prepared fast imaging sequence was implemented at 11.75 T for preclinical studies on mouse central nervous system. A strategy based on filtering the ihMT signal originating from short dipolar relaxation time (T1D) components is proposed. It involves increasing the repetition time of consecutive radiofrequency (RF) pulses of the dual saturation and allows improved signal specificity for long T1D myelinated structures. Furthermore, frequency offset, power and timing saturation parameters were adjusted to optimize the ihMT sensitivity. The optimization of the ihMT sensitivity, whilst preserving the strong specificity for the long T1D component of myelinated tissues, allowed measurements of ihMT ratios on the order of 4–5% in white matter (WM), 2.5% in gray matter (GM) and 1–1.3% in muscle. This led to high relative ihMT contrasts between myelinated tissues and others (~3–4 between WM and muscle, and ≥2 between GM and muscle). Conversely, higher ihMT ratios (~6–7% in WM) could be obtained using minimal T1D filtering achieved with short saturation pulse repetition time or cosine-modulated pulses for the dual-frequency saturation. This study represents a first stage in the process of validating ihMT as a myelin biomarker by providing optimized ihMT preclinical sequences, directly transposable and applicable to other preclinical magnetic fields and scanners. Finally, ihMT ratios measured in various central nervous system areas are provided for future reference. |
Databáze: | OpenAIRE |
Externí odkaz: |