Lower limb pneumatic compression during dobutamine stress echocardiography in patients with normal resting wall motion: will it increase diagnostic accuracy?
Autor: | Zainab Abdel-Salam, Bassem Enany, Bassem Wadie, Wail Nammas, Lawra Allam |
---|---|
Rok vydání: | 2015 |
Předmět: |
Adult
Male medicine.medical_specialty Diagnostic accuracy Coronary Artery Disease Coronary Angiography Sensitivity and Specificity Coronary artery disease Dobutamine Positive predicative value Internal medicine medicine Humans Wall motion Intermittent Pneumatic Compression Devices Aged business.industry Middle Aged Compression (physics) medicine.disease medicine.anatomical_structure Lower Extremity Cardiology Vascular resistance Female Radiology Cardiology and Cardiovascular Medicine business Echocardiography Stress medicine.drug Artery |
Zdroj: | Kardiologia Polska. 73:620-626 |
ISSN: | 1897-4279 0022-9032 |
DOI: | 10.5603/kp.a2015.0036 |
Popis: | Background: Pneumatic compression of the lower part of the body increases systemic vascular resistance and left ventricular afterload. Aim: We compared the diagnostic accuracy of dobutamine stress echocardiography (DSE) with pneumatic compression of the lower extremities, vs. standard DSE, for detection of angiographically significant coronary artery disease (CAD) in patients with normal baseline resting wall motion. Methods: We enrolled 70 consecutive patients with no resting wall motion abnormalities (WMA), who underwent DSE. DSE was repeated with pneumatic compression of the lower extremities three days after the initial standard DSE. A positive test was defined as the induction of WMA in at least two contiguous non-overlap segments at any stage of dobutamine infusion. Significant coronary stenosis was defined as ≥ 50% obstruction of ≥ 1 sizable artery by coronary angiography. Results: The mean age of the study cohort was 54.7 ± 9.9 years; 55.7% were females. Thirty-eight (54.3%) patients had significant CAD. The mean test duration was 15.8 ± 5.1 min for standard DSE and 11.7 ± 4.1 min for DSE with pneumatic compression. Analysis of standard DSE revealed sensitivity, specificity, and positive and negative predictive values of 81.6%, 90.6%, 91.2%, and 80.6%, respectively; overall accuracy was 85.7%. Analysis of DSE with pneumatic compression revealed sensitivity, specificity, and positive and negative predictive values of 89.5%, 87.5%, 89.5%, and 87.5%, respectively; overall accuracy was 88.6%. Conclusions: In symptomatic patients with suspected CAD referred for evaluation by DSE, who have no resting wall motion abnormalities, pneumatic compression of the lower extremities during DSE improved the sensitivity but slightly reduced the specificity for detection of angiographically significant CAD, compared with standard DSE. Moreover, it reduced the test duration. |
Databáze: | OpenAIRE |
Externí odkaz: |