Comparison of Bite Force with Locking Plates versus Non-Locking Plates in the Treatment of Mandibular Fractures: A Meta-Analysis
Autor: | Glaciele Maria de Souza, Endi Lanza Galvão, Ighor Andrade Fernandes, José Cristiano Ramos Glória, Ricardo Lopes Rocha, Saulo Gabriel Moreira Falci, Esmeralda Maria da Silveira |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2018 |
Předmět: |
Molar
Mandibular fracture Dentistry lcsh:Medicine bone plates internal fixators 03 medical and health sciences 0302 clinical medicine Incisor Fracture fixation Bone plate medicine 030223 otorhinolaryngology business.industry lcsh:R 030206 dentistry medicine.disease lcsh:Otorhinolaryngology lcsh:RF1-547 Confidence interval Masticatory force Bite force quotient medicine.anatomical_structure Otorhinolaryngology mandibular fracture fracture fixation bite force Systematic Review business |
Zdroj: | International Archives of Otorhinolaryngology, Vol 22, Iss 02, Pp 181-189 (2018) International Archives of Otorhinolaryngology, Volume: 22, Issue: 2, Pages: 181-189, Published: JUN 2018 International Archives of Otorhinolaryngology v.22 n.2 2018 International Archives of Otorhinolaryngology Fundação Otorrinolaringologia (FORL) instacron:FORL |
ISSN: | 1809-4864 1809-9777 |
Popis: | Introduction Mandibular fractures represent a high percentage of all facial fractures, and the bite force is a fundamental parameter to measure the actual mandibular function and, subsequently, the masticatory efficiency and quality of life. Objectives The purpose of the present systematic review was to verify if there is any difference in the bite forces of patients with mandibular fractures fixed by locking or non-locking plates, testing the null hypothesis of no difference in this parameter. Data Synthesis A systematic review of the literature was conducted using four databases (PubMed, Virtual Health Library, Web of Science and Science Direct) without restrictions as to publication date or language. We found 3,039 abstracts, and selected 4 articles for this review. Conclusion The overall results show better performance in bite force for the locking plates when compared with the non-locking plates in the incisor region (mean deviation [MD]: 1.18; 95% confidence interval [95%CI]: 0.13–2.23), right molar region (MD: 4.71; 95%CI: 0.63–8.79) and left molar region (MD: 10.34; 95%CI: 4.55–16.13). Although the results of this study indicated a better bite force result with the locking plates, there is still no sufficient evidence to support this information safely. |
Databáze: | OpenAIRE |
Externí odkaz: |