Arthroscopic Transosseous Anchorless Rotator Cuff Repair Using the X-Box Technique
Autor: | Peter Buxbaumer, Amir Steinitz, Eduard Buess, Michael Hackl |
---|---|
Rok vydání: | 2019 |
Předmět: |
Orthopedic surgery
030222 orthopedics medicine.medical_specialty business.industry Transosseous equivalent Biological healing 030229 sport sciences Gold standard (test) Surgery 03 medical and health sciences 0302 clinical medicine medicine.anatomical_structure Technical Note medicine Orthopedics and Sports Medicine Rotator cuff business RD701-811 |
Zdroj: | Arthroscopy Techniques Arthroscopy Techniques, Vol 8, Iss 2, Pp e175-e181 (2019) |
ISSN: | 2212-6287 |
DOI: | 10.1016/j.eats.2018.10.004 |
Popis: | We describe a reproducible, step-by-step arthroscopic technique for anchorless transosseous rotator cuff repair using an X-box configuration with the Arthrotunneler device. The technique uses 2 bone tunnels and 4 high-strength sutures and is suitable for medium to large tears of the supra- and infraspinatus that would alternatively need a double-row repair with 4 anchors. Biomechanically, results appear to be similar as for anchored transosseous equivalent techniques. Enhanced biological healing and lower material costs are the possible benefits of this appealing arthroscopic approach that mimics the previous gold standard. |