Measurement of melanoma thickness – comparison of two methods: Ultrasound versus morphology
Autor: | Vygintas Kaikaris, Jurgita Makštienė, Rytis Rimdeika, Kęstutis Maslauskas, Donatas Samsanavičius, Juozas Pundzius, Skaidra Valiukevičienė |
---|---|
Rok vydání: | 2011 |
Předmět: |
Adult
Male Reconstructive surgery medicine.medical_specialty Skin Neoplasms Correlation coefficient Lymphovascular invasion Biopsy Breslow Thickness Humans Medicine Prospective Studies Stage (cooking) Melanoma Aged Neoplasm Staging Skin Ultrasonography Aged 80 and over business.industry Ultrasound Reproducibility of Results Middle Aged medicine.disease Surgery Cutaneous melanoma Female business Follow-Up Studies |
Zdroj: | Journal of Plastic, Reconstructive & Aesthetic Surgery. 64:796-802 |
ISSN: | 1748-6815 |
DOI: | 10.1016/j.bjps.2010.10.008 |
Popis: | Summary Objective The aim of our study was to investigate the association between non-invasive ultrasound examination and morphologic test results in the measurement of cutaneous melanoma thickness influencing surgical treatment strategy. Methods Our prospective clinical study has been conducted in the Clinic of Plastic and Reconstructive Surgery of Kaunas University of Medicine Hospital (KUMH) since January 2004 until October 2008. A total of 100 patients with a clear clinical diagnosis of stage I–II cutaneous melanoma were enrolled in this study. Melanoma depth was measured using a linear 14-MHz frequency ultrasound sensor (Toshiba Xario XG). Surgically removed fragments of skin-subcutaneous tissue were fixated using 10% formalin solution in the operating theatre, and sent to KUMH Clinic of Pathological Anatomy. The most informative sections were analysed for tumour thickness, according to Breslow, as well as tumour type, vascular and lymphatic invasion and dissemination. A comparative data analysis of melanoma thickness measured by ultrasound (T) preoperatively and histologically estimated cutaneous melanoma (CM) thickness according to Breslow (pT) using the Bland–Altman method was performed. Results Higher mean difference of melanoma thickness (60μm) between T and pT measurements was found when tumour thickness matched pT1 and pT2 categories. In cases of CM depth exceeding 2mm, mean difference of measurements between CM thickness determined by ultrasound and histological examination was lower (30μm). Data regression analysis showed that correlation between T and pT measurements was lower when CM was thinner (1–2mm) (Pearson's correlation coefficient, r : 0.283). In cases of thicker melanoma (>2mm), strong and statistically significant ( p r : 0.869) was observed. Conclusions Correlation between melanoma thickness measured using a linear 14-MHz frequency ultrasound sensor and histologically estimated melanoma thickness according to Breslow was lower if melanoma was thinner (1–2mm). However, in cases of thicker melanoma (>2mm), very strong correlation between measurements was observed. |
Databáze: | OpenAIRE |
Externí odkaz: |