Quadriceps tendon and patellar ligament: Cryosectional anatomy and structural properties in young adults
Autor: | Lutz-Peter Nolte, P. Brunner, L. Schatzmann, H. U. Stäubli, L. Rincón |
---|---|
Rok vydání: | 1996 |
Předmět: |
Adult
Male Ultimate load Tendons Cruciate ligament Tensile Strength Freezing Ultimate tensile strength medicine Humans Ultimate failure Orthopedics and Sports Medicine Histocytological Preparation Techniques business.industry Patellar ligament Anatomy musculoskeletal system Biomechanical Phenomena medicine.anatomical_structure Ligaments Articular Ligament Surgery Patella Stress Mechanical Quadriceps tendon business |
Zdroj: | Knee Surgery, Sports Traumatology, Arthroscopy. 4:100-110 |
ISSN: | 1433-7347 0942-2056 |
DOI: | 10.1007/bf01477262 |
Popis: | Structural tensile properties analyses of 10-mm-wide central sections of quadriceps tendon-bone (QT-B) and bone-patellar ligament (B-PL) complexes from young male donors (mean age 24.9 years, range 19-32 years) were complemented by a cryosectional analysis: each QT-B complex was composed of the segment of the quadriceps tendon with the proximal half of the patella attached, each B-PL complex was composed of the distal half of the patella with the patellar ligament attached. A servohydraulic materials testing machine was used to assess ultimate failure load of 16 unconditioned and 16 preconditioned QT-B and B-PL complexes at an extension rate of 1 mm/s. Ligaments/tendons were preconditioned during 200 cycles from 50 to 800 N at 0.5 Hz. On cryosections the quadriceps tendons were significantly longer and thicker and exhibited a significantly larger bony attachment area than the patellar ligaments. Cross-sectional areas of 10-mm-wide, full-thickness, central parts of unconditioned quadriceps tendons were significantly greater and measured 64.6 +/- 8.4 mm2 with respect to the cross-sectional area of patellar ligaments, measuring 36.8 +/- 5.7 mm2 (P < 0.0025). Ultimate failure loads for unconditioned complexes resulted at 2173 +/- 618 N for QT-B complexes and at 1953 +/- 325 N for B-PL complexes (P = 0.43). Ultimate failure load values measured 2353 +/- 495 N for preconditioned QT-B complexes and 2376 +/- 152 N for preconditioned B-PL complexes, respectively (P = 0.77). Despite the fact that initial testing length, thickness, cross-sectional shape and area of unconditioned QT-B and B-PL complexes were significantly different, displacement at ultimate load, energy to failure and total energy were not. In terms of ultimate tensile strength, the 10-mm-wide central part of the QT-B complex compared favourably to the tensile properties of the human femur-anterior cruciate ligament-tibia complex from a comparable young age group. The evidence from anatomic, cryosectional and structural properties analyses suggests that the QT-B complex may be a valuable and versatile adjunct to the surgeon's armamentarium in reconstructive cruciate ligament surgery. |
Databáze: | OpenAIRE |
Externí odkaz: |