Monitoring Radiation Doses during Diagnostic and Therapeutic Neurointerventional Procedures: Multicenter Study for Establishment of Reference Levels
Autor: | See Sung Choi, Jung-Jae Kim, Dae Seob Choi, Woong Yoon, Young-Jun Lee, Pyong Jeon, Woo Sang Jeong, Dong Joon Kim, Jeong Jin Park, Bum-Soo Kim, Hae Woong Jeong, Jun Soo Byun, Jieun Rho, Chang-Woo Ryu, Yoo Dong Won, Sang Il Suh, Sang Heum Kim, Sung Hyun Baik, Noah Hong, Yunsun Song, Soo Mee Lim, Sang Hyun Suh, Yon-Kwon Ihn |
---|---|
Jazyk: | angličtina |
Rok vydání: | 2021 |
Předmět: |
medicine.medical_specialty
Medicine (General) medicine.medical_treatment intracranial arteriovenous malformation diagnostic reference levels Neurosciences. Biological psychiatry. Neuropsychiatry Kerma Aneurysm R5-920 medicine Embolization Interventional neuroradiology Original Paper medicine.diagnostic_test business.industry Arteriovenous malformation medicine.disease intracranial aneurysm Multicenter study Quartile thrombectomy cerebral angiography Radiology business radiation monitoring Cerebral angiography RC321-571 |
Zdroj: | Neurointervention, Vol 16, Iss 3, Pp 240-251 (2021) Neurointervention |
ISSN: | 2233-6273 2093-9043 |
Popis: | Purpose: To assess patient radiation doses during diagnostic and therapeutic neurointerventional procedures from multiple centers and propose dose reference level (RL).Materials and Methods: Consecutive neurointerventional procedures, performed in 22 hospitals from December 2020 to June 2021, were retrospectively studied. We collected data from a sample of 429 diagnostic and 731 therapeutic procedures. Parameters including dose-area product (DAP), cumulative air kerma (CAK), fluoroscopic time (FT), and total number of image frames (NI) were obtained. RL were calculated as the 3rd quartiles of the distribution.Results: Analysis of 1160 procedures from 22 hospitals confirmed the large variability in patient dose for similar procedures. RLs in terms of DAP, CAK, FT, and NI were 101.6 Gy·cm2, 711.3 mGy, 13.3 minutes, and 637 frames for cerebral angiography, 199.9 Gy·cm2, 3,458.7 mGy, 57.3 minutes, and 1,000 frames for aneurysm coiling, 225.1 Gy·cm2, 1,590 mGy, 44.7 minutes, and 800 frames for stroke thrombolysis, 412.3 Gy·cm2, 4,447.8 mGy, 99.3 minutes, and 1,621.3 frames for arteriovenous malformation (AVM) embolization, respectively. For all procedures, the results were comparable to most of those already published. Statistical analysis showed male and presence of procedural complications were significant factors in aneurysmal coiling. Male, number of passages, and procedural combined technique were significant factors in stroke thrombolysis. In AVM embolization, a significantly higher radiation dose was found in the definitive endovascular cure group.Conclusion: Various RLs introduced in this study promote the optimization of patient doses in diagnostic and therapeutic interventional neuroradiology procedures. Proposed 3rd quartile DAP (Gy·cm2) values were 101.6 for diagnostic cerebral angiography, 199.9 for aneurysm coiling, 225.1 for stroke thrombolysis, and 412.3 for AVM embolization. Continual evolution of practices and technologies requires regular updates of RLs. |
Databáze: | OpenAIRE |
Externí odkaz: |