Influência do envelhecimento sobre a rugosidade e estabilidade de cor dos cimentos de ionômero de vidro encapsulados
Autor: | Adriana Bona Matos, Beatriz Togoro Ferreira da Silva, Erika Michele dos Santos Araújo, Bruno Bachiega da Silva |
---|---|
Rok vydání: | 2019 |
Předmět: |
Physics
Aging Envelhecimento Glass Ionomer Cement Color 02 engineering and technology 010402 general chemistry 021001 nanoscience & nanotechnology 01 natural sciences 0104 chemical sciences General Earth and Planetary Sciences Cor 0210 nano-technology Cimento de Ionômero de Vidro General Environmental Science Nuclear chemistry |
Zdroj: | Clinical and Laboratorial Research in Dentistry; 2019 Clinical and Laboratorial Research in Dentistry Universidade de São Paulo (USP) instacron:USP |
ISSN: | 2357-8041 |
DOI: | 10.11606/issn.2357-8041.clrd.2019.154506 |
Popis: | Objetivo: Analisar efeitos de diferentes envelhecimentos sobre a rugosidade e a cor de cimentos de ionômero de vidro (CIV) encapsulados. Materiais e métodos: Foram testados dois cimentos de ionômero de vidro [convencional/ Self Cure (SC) e resino modificado/Light Cure (LC)] e envelhecimentos [(baseline, pós-ciclagem térmica e pós- -ciclagem térmica + armazenamento por sete meses)]. 52 discos (n = 13) foram confeccionados. A cor foi avaliada por dois espectrofotômetros (VITA Easyshade e Konica Minolta CE3700A), e a rugosidade pelo perfilômetro óptico (Proscan 2100, Scantron). Resultados: ANOVA dois fatores e teste de Tukey (p < 0,05) foram realizados. Os CIVs apresentaram diferenças estatisticamente significantes entre si (p < 0,05) para rugosidade (SC = 0,202 μm e LC = 0,241), os envelhecimentos alteraram significativamente a rugosidade baseline = 0,278 μm, ciclado = 0,220 μm e ciclado-armazenado = 0,167 μm, e para cor (SC ΔE = 3,89 e o LC ΔE = 4,94). Para ΔL*, Δa*, Δb* houve diferença na interação dos fatores, com maior alteração do ΔL* para o CIV LC após ciclagem + armazenagem. Para Δa* houve diferença estatisticamente significante (p < 0,05) entre os envelhecimentos, sendo maior para o grupo CIV LC após ciclagem. Maior alteração Δb* foi observada para o CIV LC após ciclagem + armazenagem. Conclusões: Os diferentes CIVs possuem rugosidade superficial e cor diferentes. O CIV LC mostrou-se mais rugoso quando comparado ao SC, porém ambos se tornaram menos rugosos com o passar do tempo. O protocolo de envelhecimento que mais interfere na rugosidade e na cor de diferentes tipos de CIV é a ciclagem térmica seguida de armazenamento. Objective: To analyze effects of differents agings on the roughness and color of different encapsulated glass ionomer cements (GIC). Materials and methods: Two glass ionomer cements (Conventional/Self Cure (SC) and modified resin/Light Cure (LC)) and three aging (baseline, post-thermal cycling and post-thermal cycling + storage for 7 months). Fifty-two discs (n = 13) were made. The color stability was performed with spectrophotometers (VITA Easyshade and Konica Minolta CE3700A), and the roughness test with optical profilometer (Proscan 2100, Scantron). Results: The data were analyzed with two-way ANOVA and Tukey’s test (p < 0.05). The GICs presented statistically significancy when compared (p < 0.05), for roughness (SC = 0,202μm e LC = 0,241), the aging protocols tested promoted a significant change in surface roughness baseline = 0,278μm, post-cycling = 0,220μm and storage = 0,167μm and for the color (SC ΔE = 3,89 and LC ΔE = 4,94). However, the interaction between the factors was not statistically significant (p > 0.05). For ΔL*, Δa*, Δb*, there was a difference in the interaction of the factors, with a greater change in ΔL* for the GIC LC post-thermal cycling + storage). For Δa* there was a statistically significant difference (p < 0.05) between aging, being the higher alteration for the GIC LC group post-thermal cycling. Greater change in the b* coordinate was observed for the GIC LC post-thermal cycling + storage. Conclusions: The different GICs presented different surface roughness and color. The resin-modified GIC LC showed to be rougher when compared to the conventional GIC SC. However, both GICs became less rough over time. The post-thermal cycling + storage for 7 months was the aging protocol that most interfered in the roughness and color of different types of GICs. |
Databáze: | OpenAIRE |
Externí odkaz: |